3phase Power Analyzer TES-3600

Power KW, KVAR, KVA, PF, θ ,Hz .
1P2W, 1P3W, 3P3W2M & 3P4W Power Measurement.
Connectors for 4 Current Sensing Clamps
Availability: Out of stock
Manufacturer: TES
341,200,000 ریال
ریال

 3phase Power Analyzer model TES-3600:

TES-3600 3P Power Analyzer

  • 10 Display Easy - to - View LCD Screen.
  • Connectors for 4 Current Sensing Clamps.
  • 1P2W, 1P3W, 3P3W2M & 3P4W Power Measurement.
  • True RMS Sensing.
  • Power KW, KVAR, KVA, PF, θ ,Hz, & 
    Energy KWh, KVARh & KVAh Measurement.
  • Phase sequency indicator function.

       SPECIFICATION:

 

Voltage Measurement (V)
Ranges

Method

Accuracy
Input impedance
999.9V
True RMS
± 0.5%rdg ± 10dgts (>30V)
2M Ω
Current Measurement (A)
Ranges
Method
Accuracy
250A 、 500A 、 1000A

True RMS

± 0.5%rdg ± 10dgts+clamp on sensor specifications

Active Power Measurement (KW)
Ranges

Accuracy

Effect of power factor
600.0KW
± 0.5%rdg ± 10dgts+clamp on sensor specifications

± 0.1%rdg

Reactive Power Measurement (KVAR)
Ranges
Accuracy
Effect of power factor
600.0KVAR
± 0.5%rdg ± 10dgts+clamp on sensor specifications
± 0.1%rdg
Apparent Power Measurement (KVA)
Ranges
Accuracy
600.0KVA
± 0.5%rdg ± 10dgts+clamp on sensor specifications
Power Integration Measurement
Power Integration
Resolution
Accuracy
0.0KWh to 9999MWh
0.1KWh
± 0.5%rdg ± 10dgts+clamp on sensor specifications
0.0Kvarh to 9999Mvarh
0.1Kvarh
0.0KVAh to 9999MVAh
0.1KVAh
Power Factor Measurement
Ranges
Accuracy
Polarity display
-1.000(lead) to 0.000 to + 1.000 (lag)

± 1dgt for each calculation from measured values

When the current lags the voltage unsigned ; when the current leads the voltage : "-".
Frequency Measurement
Ranges
Measurement source
Accuracy
40Hz to 100Hz
Voltage U1
± 0.5%rdg ± 1dgt
General Specifications
Size 235(L)x116(W)x54(H)mm (9.3"Lx4.6"Wx2.1"H)
Operating Temperature and Humidity 0 ℃ to 50 ℃ (32 ℉ to 122 ℉ ) R.H. < 80% non-condensing
Storage Temperature and Humidity - 10 ℃ to 60 ℃ (14 ℉ to 140 ℉ ) R.H. < 70% non-condensing
Accessories

Instruction manual , Software CD Rom / Optical RS-232 interface , Deluxe carrying case , Battery (“AA” 1.5V ′ 8pcs ) , AC adaptor (110V -> 12V ; 220V -> 12V) , 4pcs current clamp transducer (1, 2, 3, 4 cable length 3 meters) (1000A AC, jaw opening 40mm) , 4pcs crocodiles test leads (blue, yellow, red, black, wire length 3 meters)

 3phase Power Analyzer model TES-3600:

TES-3600 3P Power Analyzer

  • 10 Display Easy - to - View LCD Screen.
  • Connectors for 4 Current Sensing Clamps.
  • 1P2W, 1P3W, 3P3W2M & 3P4W Power Measurement.
  • True RMS Sensing.
  • Power KW, KVAR, KVA, PF, θ ,Hz, & 
    Energy KWh, KVARh & KVAh Measurement.
  • Phase sequency indicator function.

       SPECIFICATION:

 

Voltage Measurement (V)
Ranges

Method

Accuracy
Input impedance
999.9V
True RMS
± 0.5%rdg ± 10dgts (>30V)
2M Ω
Current Measurement (A)
Ranges
Method
Accuracy
250A 、 500A 、 1000A

True RMS

± 0.5%rdg ± 10dgts+clamp on sensor specifications

Active Power Measurement (KW)
Ranges

Accuracy

Effect of power factor
600.0KW
± 0.5%rdg ± 10dgts+clamp on sensor specifications

± 0.1%rdg

Reactive Power Measurement (KVAR)
Ranges
Accuracy
Effect of power factor
600.0KVAR
± 0.5%rdg ± 10dgts+clamp on sensor specifications
± 0.1%rdg
Apparent Power Measurement (KVA)
Ranges
Accuracy
600.0KVA
± 0.5%rdg ± 10dgts+clamp on sensor specifications
Power Integration Measurement
Power Integration
Resolution
Accuracy
0.0KWh to 9999MWh
0.1KWh
± 0.5%rdg ± 10dgts+clamp on sensor specifications
0.0Kvarh to 9999Mvarh
0.1Kvarh
0.0KVAh to 9999MVAh
0.1KVAh
Power Factor Measurement
Ranges
Accuracy
Polarity display
-1.000(lead) to 0.000 to + 1.000 (lag)

± 1dgt for each calculation from measured values

When the current lags the voltage unsigned ; when the current leads the voltage : "-".
Frequency Measurement
Ranges
Measurement source
Accuracy
40Hz to 100Hz
Voltage U1
± 0.5%rdg ± 1dgt
General Specifications
Size 235(L)x116(W)x54(H)mm (9.3"Lx4.6"Wx2.1"H)
Operating Temperature and Humidity 0 ℃ to 50 ℃ (32 ℉ to 122 ℉ ) R.H. < 80% non-condensing
Storage Temperature and Humidity - 10 ℃ to 60 ℃ (14 ℉ to 140 ℉ ) R.H. < 70% non-condensing
Accessories

Instruction manual , Software CD Rom / Optical RS-232 interface , Deluxe carrying case , Battery (“AA” 1.5V ′ 8pcs ) , AC adaptor (110V -> 12V ; 220V -> 12V) , 4pcs current clamp transducer (1, 2, 3, 4 cable length 3 meters) (1000A AC, jaw opening 40mm) , 4pcs crocodiles test leads (blue, yellow, red, black, wire length 3 meters)