The Carbon Monoxide Transmitter model HT6 has a serial port MODBUS / RTU-RS485. This device can be ordered in a variety of ranges for Measuring Carbon Monoxide Gas (lethal CO gas). A custom output voltage of 0 to 10 volts (0to10V) and a output current of 4 to 20 mA (4to20mA) are placed on the device. Each channel operates independently and can be set to different values. Analog output values can be adjusted by the software. The Carbon Monoxide Sensor is calibrated at a gas concentration of 50 ppm in the factory and can be calibrated in reputable laboratories by the software provided.
Custom range of Carbon Monoxide gas sensor HT6
1) Range 0 to 1000ppm Accuracy (± 5% R) China sensor type, 5 years life in clean air
This Carbon Monoxide Detector is capable of withstanding conditions up to 1000ppm. This sensor shows good sensitivity to low concentrations and is suitable for places where carbon monoxide is not normally present in those conditions (such as greenhouses, air conditioning systems, etc.).
2) Range 0 to 1000ppm Accuracy (± 5% R) Figaro sensor type, 10 years life in fresh air
This Carbon Monoxide Detector is capable of withstanding conditions up to 10000ppm. This sensor is suitable for places where carbon monoxide is normally present (such as parking lots, tunnels, furnaces, etc.).
Technical Specifications HT6:
Power supply (non-isolated): 24Vdc ± 10%
Serial port: MODBUS / RTU-RS485 communication protocol Send rate 2400 ~ 57600b / s None, Odd, Even parity
Analog output (10bit): 4 to 20mA current output and 0 to 10V voltage output, 100ms response time
Environmental conditions: Operating temperature -20 to 60 degrees Celsius, humidity 0 to 95%
Length × width × height 127 × 70 × 52 mm
Weight: 300gr