Search
Filters
Close

Fluke 789 Process Meter

Voltage AC/DC:400.0 mV/1000 V
Current AC/DC:1.000 A (0.440 A continuous)
Resistance:400.0 oh,m, 4.000 k, 40.00 k, 400.0 k, 4.0 M, 40 M
Frequency:199.99 Hz, 1999.9 Hz, 19.999 kHz
Availability: Out of stock
Manufacturer: Fluke
ریال

The Fluke 789 ProcessMeter combines a loop calibrator with a DMM to give process technicians double the power in one tool. Fluke 789 has a display thats twice as large and twice as bright with two levels of backlighting. The 789 loop calibrators also have a built-in, selectable 250 ohm HART ® resistor, eliminating the need to carry a separate resistor.

Built with Fluke Connect

1000 V RMS max voltage applied between any jack and earth ground

storage temperature: -40° to 140°F (-40° to 60°C) 

operating temperature: -4° to 131°F (-20° to 55°C) 

Range and resolutions:

V DC: 400.mV, 4.000 V, 40.00 V, 400.0 V, 1000 V

V AC (true-rms): 400.0 mV, 4.000 V, 40.00 V, 400.0 V, 1000 V

mA DC: 30.000 mA

A DC: 1.000 A (0.440 A continuous)

A AC: 1.000 A (0.440 A continuous)

The Fluke 789 ProcessMeter combines a loop calibrator with a DMM to give process technicians double the power in one tool. Fluke 789 has a display thats twice as large and twice as bright with two levels of backlighting. The 789 loop calibrators also have a built-in, selectable 250 ohm HART ® resistor, eliminating the need to carry a separate resistor.

Built with Fluke Connect

1000 V RMS max voltage applied between any jack and earth ground

storage temperature: -40° to 140°F (-40° to 60°C) 

operating temperature: -4° to 131°F (-20° to 55°C) 

Range and resolutions:

V DC: 400.mV, 4.000 V, 40.00 V, 400.0 V, 1000 V

V AC (true-rms): 400.0 mV, 4.000 V, 40.00 V, 400.0 V, 1000 V

mA DC: 30.000 mA

A DC: 1.000 A (0.440 A continuous)

A AC: 1.000 A (0.440 A continuous)

Products specifications
Attribute name Attribute value
Producer Fluke
Made in United States of America
device type Portable
Display screen very large dual display with two-level backlight
Battery 4 AA alkaline batteries
Storage temperature -40 °C to 60 °C
Working temperature -20 °C to 55 °C
Working humidity 95% up to 30°C 75% up to 40°C 45% up to 50°C 35% up to 55°C
Frequency range measurement to 19.999 kHz
DC voltage 400.0 mV, 4.000 V, 40.00 V, 400.0 V, 1000 V
AC voltage 400.0 mV, 4.000 V, 40.00 V, 400.0 V, 1000 V
DC Current 0-1 A
AC Current 0-1 A
Range of resistance measurements 400.0 Ohms, 4.000 k, 40.00 k, 400.0 k, 4.0 M, 40 M
Dimensions 50 x 100 x 203 mm
Weight 610 g