OptiFiber® Pro OTDR

Wavelengths:850 nm,1300 nm,1310 nm,1550 nm
Max distance range setting: 40 km, 130 km
Availability: Out of stock
Manufacturer: Fluke
ریال

The Fluke Networks OptFiber PRO is the optical loss-testing part. OTDR modules are available either in MultiMode, SingleMode or Quad versions. Additionally, Transcat recommends each version be purchased with double-ended inspection kits.This fiber optic inspection scope provides automated PASS/FAIL certification take the guess work out of fiber inspection so anyone can be a fiber expert. It also comes with an optional fiber optic cleaning kit.OptiFiber® Pro OTDR price is available in sensotec website.

 

OptiFiber Pro OTDR specifications:

 

  Multimode module Singlemode module Quad module
Wavelengths 850 nm +/- 10 nm
1300 nm +35/-15 nm
1310 nm +/- 25 nm
1550 nm +/- 30 nm
850 nm +/- 10 nm
1300 nm +35/-15 nm
1310 nm +/- 25 nm
1550 nm +/- 30 nm
Compatible fiber types 50/125 µm
62.5/125 µm
Singlemode 50/125 µm
62.5/125 µm
Singlemode
Event dead zone 1 850 nm: 0.5 m typical
1300 nm: 0.7 m typical
1310 nm: 0.6 m typical
1550 nm: 0.6 m typical
850 nm: 0.5 m typical
1300 nm: 0.7 m typical
1310 nm: 0.6 m typical
1550 nm: 0.6 m typical
Attenuation dead zone 2 850 nm: 2.5 m typical
1300 nm: 4.5 m typical
1310 nm: 3.6 m typical
1550 nm: 3.7 m typical
850 nm: 2.5 m typical
1300 nm: 4.5 m typical
1310 nm: 3.6 m typical
1550 nm: 3.7 m typical
Dynamic range 3, 5, 6 850 nm: 28 dB typical
1300 nm: 30 dB typical
1310 nm: 32 dB typical
1550 nm: 30 dB typical
850 nm: 28 dB typical
1300 nm: 30 dB typical
1310 nm: 32 dB typical
1550 nm: 30 dB typical
Max distance range setting 40 km 130 km MM: 40 km
SM: 130 km
Distance measurement range 4, 5, 7, 8, 9, 10 850 nm: 9 km
1300 nm: 35 km
1310 nm: 80 km
1550 nm: 130 km
850 nm: 9 km
1300 nm: 35 km
1310 nm: 80 km
1550 nm: 130 km
Reflectance range 4, 5 850 nm: -14 dB to -57 dB (typical)
1300 nm: -14 dB to -62 dB (typical)
1310 nm: -14 dB to -65 dB (typical)
1550 nm: -14 dB to -65 dB (typical)
850 nm: -14 dB to -57 dB (typical)
1300 nm: -14 dB to -62 dB (typical)
1310 nm: -14 dB to -65dB (typical)
1550 nm: -14 dB to -65 dB (typical)
Sample resolution 3 cm to 400 cm 3 cm to 400 cm 3 cm to 400 cm
Pulse widths (nominal) 850 nm: 3, 5, 20, 40, 200 ns
1300 nm: 3, 5, 20, 40, 200, 1000 ns
1310/1550 nm: 3, 10, 30, 100, 300, 1000, 3000, 10000, 20000 ns 850 nm: 3, 5, 20, 40, 200 ns
1300 nm: 3, 5, 20, 40, 200, 1000 ns
1310/1550 nm: 3, 10, 30, 100, 300, 1000, 3000, 10000, 20000 ns

 

The Fluke Networks OptFiber PRO is the optical loss-testing part. OTDR modules are available either in MultiMode, SingleMode or Quad versions. Additionally, Transcat recommends each version be purchased with double-ended inspection kits.This fiber optic inspection scope provides automated PASS/FAIL certification take the guess work out of fiber inspection so anyone can be a fiber expert. It also comes with an optional fiber optic cleaning kit.OptiFiber® Pro OTDR price is available in sensotec website.

 

OptiFiber Pro OTDR specifications:

 

  Multimode module Singlemode module Quad module
Wavelengths 850 nm +/- 10 nm
1300 nm +35/-15 nm
1310 nm +/- 25 nm
1550 nm +/- 30 nm
850 nm +/- 10 nm
1300 nm +35/-15 nm
1310 nm +/- 25 nm
1550 nm +/- 30 nm
Compatible fiber types 50/125 µm
62.5/125 µm
Singlemode 50/125 µm
62.5/125 µm
Singlemode
Event dead zone 1 850 nm: 0.5 m typical
1300 nm: 0.7 m typical
1310 nm: 0.6 m typical
1550 nm: 0.6 m typical
850 nm: 0.5 m typical
1300 nm: 0.7 m typical
1310 nm: 0.6 m typical
1550 nm: 0.6 m typical
Attenuation dead zone 2 850 nm: 2.5 m typical
1300 nm: 4.5 m typical
1310 nm: 3.6 m typical
1550 nm: 3.7 m typical
850 nm: 2.5 m typical
1300 nm: 4.5 m typical
1310 nm: 3.6 m typical
1550 nm: 3.7 m typical
Dynamic range 3, 5, 6 850 nm: 28 dB typical
1300 nm: 30 dB typical
1310 nm: 32 dB typical
1550 nm: 30 dB typical
850 nm: 28 dB typical
1300 nm: 30 dB typical
1310 nm: 32 dB typical
1550 nm: 30 dB typical
Max distance range setting 40 km 130 km MM: 40 km
SM: 130 km
Distance measurement range 4, 5, 7, 8, 9, 10 850 nm: 9 km
1300 nm: 35 km
1310 nm: 80 km
1550 nm: 130 km
850 nm: 9 km
1300 nm: 35 km
1310 nm: 80 km
1550 nm: 130 km
Reflectance range 4, 5 850 nm: -14 dB to -57 dB (typical)
1300 nm: -14 dB to -62 dB (typical)
1310 nm: -14 dB to -65 dB (typical)
1550 nm: -14 dB to -65 dB (typical)
850 nm: -14 dB to -57 dB (typical)
1300 nm: -14 dB to -62 dB (typical)
1310 nm: -14 dB to -65dB (typical)
1550 nm: -14 dB to -65 dB (typical)
Sample resolution 3 cm to 400 cm 3 cm to 400 cm 3 cm to 400 cm
Pulse widths (nominal) 850 nm: 3, 5, 20, 40, 200 ns
1300 nm: 3, 5, 20, 40, 200, 1000 ns
1310/1550 nm: 3, 10, 30, 100, 300, 1000, 3000, 10000, 20000 ns 850 nm: 3, 5, 20, 40, 200 ns
1300 nm: 3, 5, 20, 40, 200, 1000 ns
1310/1550 nm: 3, 10, 30, 100, 300, 1000, 3000, 10000, 20000 ns

 

Products specifications
Attribute name Attribute value
Producer Fluke
Made in United States of America
device type Portable
Response wavelength 850 nm, 1300 nm, 1310 nm , 1550 nm
Working temperature -18º C to 45º C
Storage temperature -30º C to 60º C
Powered by Lithium ion battery pack, 7.2 volts
Dimensions 6.67 cm x 13.33 cm x 27.94 cm)
Weight 1.28 kg