HP-36K Mini Multimeter

Basic function
DC Voltage       400mV~1000V
AC Voltage       4V~750V
DC Current       400μA~10A
ACCurrent        400μA~10A
Resistance       400Ω~40MΩ
Capacitance     40nF~200uF
Frequency        4KHz~20MHz
Express function
Display                     3999
Range Select            AUTO
Diode Test                √
hEF Test                  √
Continuity Buzzer      
Date Hold√                 
Back Light               √
Auto Power Off         √
Battery Type        1.5V(AAA)x2
Dimension           143x75x32mm
Weight                   200g
Ctn Size                478x330x330mm
Q'TY / Ctn             60
GW/TW                18/17Kg

 

Range

Resolution

Accuracy

Remark

DC Voltage

400mV

0.1mV

±(0.8% of rdg )

-- Input Impendence: 10MΩ

-- Overload protection: 250V for 400mV range, effective DC or AC 1000V for other ranges

4V

1mV

±(0.8% of rdg)

40V

10mV

±(0.8% of rdgs)

400V

100mV

±(0.8% of rdg)

1000V

1V

±(1.5% of rdg )

AC Voltage

4V

1mV

±(1.2% of rdg)

-- Frequency Range: 40 to 400Hz,40 to 100Hz for ranges 400V & 750V

-- Response: average, calibrated in rms of sine wave

40V

10mV

±(1.2% of rdg)

400V

100mV

±(1.2% of rdg)

750V

1V

±(2.5% of rdg)

DC Current

400μA

0.1μA

±(1.5% of rdg)

-- Overload protection: F500mA/250V fuse

Note: 4A & 10A ranges are not fused  10A up to 10 seconds

4000μA

1μA

±(1.5% of rdg )

40mA

10μA

±(1.0% of rdg)

400mA

100μA

±(1.5% of rdg)

4A

1mA

±(1.8% of rdg)

10A

10mA

±(3.0% of rdg)

AC Current

400μA

0.1μA

±(1.8% of rdg)

-- Overload protection: F 500mA/250V fuse Note: 4A & 10A ranges are not fused  10A up to 10 seconds

-- Frequency Range: 40 to 400Hz

-- Response: average, calibrated in rms of sine wave

4000μA

1μA

±(2.0% of rdg)

40mA

10μA

±(1.3% of rdg)

400mA

100μA

±(1.8% of rdg)

4A

1mA

±(2.0% of rdg)

10A

10mA

±(3.0% of rdg)

Resistance

400Ω

0.1Ω

±(1.8% of rdg)

-- over-load protection: 250V effective value

4kΩ

±(1.8% of rdg)

40kΩ

10Ω

±(1.8% of rdg)

400kΩ

100Ω

±(1.8% of rdg)

4MΩ

1kΩ

±(1.8% of rdg)

40MΩ

10kΩ

±(2.0% of rdg)

Capacitor

40nF

0.01nF

±(3.5% of rdg)

-- over-load protection: 250V effective value

400nF

0.1nF

±(3.0% of rdg)

4μF

1nF

±(3.0% of rdg)

40μF

10nF

±(3.0% of rdg)

100μF

100nF

±(3.0% of rdg)

Frequency Testing

4kHz

1Hz

±(0.5% of rdg)

-- Overload Protection: 250V DC or rms AC,  Sensitivity: Range of input voltage:1.5V~10V, If input voltage over range,need adjust

40kHz

10Hz

±(0.5% of rdg)

400kHz

100Hz

±(0.5% of rdg)

4MHz

1kHz

±(0.5% of rdg)

20MHz

10kHz

±(0.5% of rdg)

Transistor hFE Test

Range

Test Range

Test Current / voltage

 

NPN & PNP

0-1000

Ib=10μA / Vce=2.4V

Diode Test

Range

Resolution

Function

-- over-load Protection: 250V effective value, forward DC current: approximate 0.5mA Reversed DC voltage: approximate 1.5V

1mV

Display: read approximate forward voltage of diode

Continuity

Range

Function

-- over-load protection: 250V effective value

n  open circuit voltage: approximate 0.5V

Built-in buzzer will sound if resistance is lover than 50Ω

 

 

HP-36K Mini Multimeter

Basic function
DC Voltage       400mV~1000V
AC Voltage       4V~750V
DC Current       400μA~10A
ACCurrent        400μA~10A
Resistance       400Ω~40MΩ
Capacitance     40nF~200uF
Frequency        4KHz~20MHz
Express function
Display                     3999
Range Select            AUTO
Diode Test                √
hEF Test                  √
Continuity Buzzer      
Date Hold√                 
Back Light               √
Auto Power Off         √
Battery Type        1.5V(AAA)x2
Dimension           143x75x32mm
Weight                   200g
Ctn Size                478x330x330mm
Q'TY / Ctn             60
GW/TW                18/17Kg

 

Range

Resolution

Accuracy

Remark

DC Voltage

400mV

0.1mV

±(0.8% of rdg )

-- Input Impendence: 10MΩ

-- Overload protection: 250V for 400mV range, effective DC or AC 1000V for other ranges

4V

1mV

±(0.8% of rdg)

40V

10mV

±(0.8% of rdgs)

400V

100mV

±(0.8% of rdg)

1000V

1V

±(1.5% of rdg )

AC Voltage

4V

1mV

±(1.2% of rdg)

-- Frequency Range: 40 to 400Hz,40 to 100Hz for ranges 400V & 750V

-- Response: average, calibrated in rms of sine wave

40V

10mV

±(1.2% of rdg)

400V

100mV

±(1.2% of rdg)

750V

1V

±(2.5% of rdg)

DC Current

400μA

0.1μA

±(1.5% of rdg)

-- Overload protection: F500mA/250V fuse

Note: 4A & 10A ranges are not fused  10A up to 10 seconds

4000μA

1μA

±(1.5% of rdg )

40mA

10μA

±(1.0% of rdg)

400mA

100μA

±(1.5% of rdg)

4A

1mA

±(1.8% of rdg)

10A

10mA

±(3.0% of rdg)

AC Current

400μA

0.1μA

±(1.8% of rdg)

-- Overload protection: F 500mA/250V fuse Note: 4A & 10A ranges are not fused  10A up to 10 seconds

-- Frequency Range: 40 to 400Hz

-- Response: average, calibrated in rms of sine wave

4000μA

1μA

±(2.0% of rdg)

40mA

10μA

±(1.3% of rdg)

400mA

100μA

±(1.8% of rdg)

4A

1mA

±(2.0% of rdg)

10A

10mA

±(3.0% of rdg)

Resistance

400Ω

0.1Ω

±(1.8% of rdg)

-- over-load protection: 250V effective value

4kΩ

±(1.8% of rdg)

40kΩ

10Ω

±(1.8% of rdg)

400kΩ

100Ω

±(1.8% of rdg)

4MΩ

1kΩ

±(1.8% of rdg)

40MΩ

10kΩ

±(2.0% of rdg)

Capacitor

40nF

0.01nF

±(3.5% of rdg)

-- over-load protection: 250V effective value

400nF

0.1nF

±(3.0% of rdg)

4μF

1nF

±(3.0% of rdg)

40μF

10nF

±(3.0% of rdg)

100μF

100nF

±(3.0% of rdg)

Frequency Testing

4kHz

1Hz

±(0.5% of rdg)

-- Overload Protection: 250V DC or rms AC,  Sensitivity: Range of input voltage:1.5V~10V, If input voltage over range,need adjust

40kHz

10Hz

±(0.5% of rdg)

400kHz

100Hz

±(0.5% of rdg)

4MHz

1kHz

±(0.5% of rdg)

20MHz

10kHz

±(0.5% of rdg)

Transistor hFE Test

Range

Test Range

Test Current / voltage

 

NPN & PNP

0-1000

Ib=10μA / Vce=2.4V

Diode Test

Range

Resolution

Function

-- over-load Protection: 250V effective value, forward DC current: approximate 0.5mA Reversed DC voltage: approximate 1.5V

1mV

Display: read approximate forward voltage of diode

Continuity

Range

Function

-- over-load protection: 250V effective value

n  open circuit voltage: approximate 0.5V

Built-in buzzer will sound if resistance is lover than 50Ω

 

 

Products specifications
Attribute name Attribute value
Made in Hong Kong
Producer HoldPeak
Dimensions 143*75*32 mm
device type Portable
Weight 200g
Also Bought

carbon monoxide alarm GS811

CO range:20PPM to 999PPM
alarm for more than 85db
$