Search
Filters
Close

TES-2732A Data logger

TES-2732A True RMS Multimeter
Item Number:
Availability: Out of stock
Manufacturer: TES
43,700,000 ریال
ریال

Data logging Multi meter model TES-2732A

Voltage (AC/DC)
Range 200m/2/20/200/750(AC)/1000V(DC) 
Accuracy: DC - ( 0.5% rdg + 1 dgt ) 
AC - ( 1.0% rdg + 5 dgts )
Resolution 0.1m
Input Impedance 10MΩ
Overload Protection 600Vrms
Resistance (Ω )
Range 200/2K/20K/200K/2M/20M
Accuracy 0.8% rdg + 2 dgts
Resolution 0.1 Ω
Overload Protection 600Vrms
Max. Open Circuit Voltage 3.2V
Max. Allowable Applied Voltage 500Vrms
Diode Test
Resolution 1mV
Accuracy 2% rdg +2 dgts
Max. Test Current 1.0mA
Max. Open Circuit Voltage 3.2V
Capacitance (F)
Range 2000p/200n/2 m /20 m F
Accuracy 3% rdg + 10 dgts
Test Frequency 400Hz
Data logger function for TES-2732 only
Continuity Beeper
Operation Resistance Below 30 Ω
Max. Open Circuit Voltage 3.2V
Frequency (Hz)
Test Range 10Hz to 20MHz (Auto Range)
Range 2K/20K/200K/2M/20MHz
Resolution 1 Hz
Accuracy 0.5% rdg + 2 dgts
Input Sensitivity 100mV
Max. Allowable Applied Voltage 600Vrms.
Current (AC/DC)
Range 200 m /2m/20m/200m/20A (AC/DC)
Accuracy DC - ( 1.0% rdg + 1dgt ) 
AC - ( 1.2% rdg + 3dgts )
Resolution 0.1 μ A
Burden Voltage 0.35V
Overload Protection 0.5A/250V Fast Blow Fuse & Diode 20A/380V
Specifications
Size & Weight 180mm(L) x 82mm(W) x 38mm(H) & 365g
Accessories Test leads, Spare Fuse, Battery, 
Operation Instruction, 
Optional rubber holster. 
Connecting Cable & Software 
disc for TES-2730/2732
Temperature
Range -50℃ to 1370℃
-50℉ to 1999℉
Resolution 0.1℃ & 0.1℉
Sensor "K" type

Display: 
3-1/2 Digital LCD Display 
Maximum Reading 1999 
Sampling Rate: 2.5 readings per second

Operation/Storage Condition: 
0℃ to 40℃ & 80% R.H. 
-10℃ to 60℃ < 70% R.H. 
Power Source: one 9V Battery

Data logging Multi meter model TES-2732A

Voltage (AC/DC)
Range 200m/2/20/200/750(AC)/1000V(DC) 
Accuracy: DC - ( 0.5% rdg + 1 dgt ) 
AC - ( 1.0% rdg + 5 dgts )
Resolution 0.1m
Input Impedance 10MΩ
Overload Protection 600Vrms
Resistance (Ω )
Range 200/2K/20K/200K/2M/20M
Accuracy 0.8% rdg + 2 dgts
Resolution 0.1 Ω
Overload Protection 600Vrms
Max. Open Circuit Voltage 3.2V
Max. Allowable Applied Voltage 500Vrms
Diode Test
Resolution 1mV
Accuracy 2% rdg +2 dgts
Max. Test Current 1.0mA
Max. Open Circuit Voltage 3.2V
Capacitance (F)
Range 2000p/200n/2 m /20 m F
Accuracy 3% rdg + 10 dgts
Test Frequency 400Hz
Data logger function for TES-2732 only
Continuity Beeper
Operation Resistance Below 30 Ω
Max. Open Circuit Voltage 3.2V
Frequency (Hz)
Test Range 10Hz to 20MHz (Auto Range)
Range 2K/20K/200K/2M/20MHz
Resolution 1 Hz
Accuracy 0.5% rdg + 2 dgts
Input Sensitivity 100mV
Max. Allowable Applied Voltage 600Vrms.
Current (AC/DC)
Range 200 m /2m/20m/200m/20A (AC/DC)
Accuracy DC - ( 1.0% rdg + 1dgt ) 
AC - ( 1.2% rdg + 3dgts )
Resolution 0.1 μ A
Burden Voltage 0.35V
Overload Protection 0.5A/250V Fast Blow Fuse & Diode 20A/380V
Specifications
Size & Weight 180mm(L) x 82mm(W) x 38mm(H) & 365g
Accessories Test leads, Spare Fuse, Battery, 
Operation Instruction, 
Optional rubber holster. 
Connecting Cable & Software 
disc for TES-2730/2732
Temperature
Range -50℃ to 1370℃
-50℉ to 1999℉
Resolution 0.1℃ & 0.1℉
Sensor "K" type

Display: 
3-1/2 Digital LCD Display 
Maximum Reading 1999 
Sampling Rate: 2.5 readings per second

Operation/Storage Condition: 
0℃ to 40℃ & 80% R.H. 
-10℃ to 60℃ < 70% R.H. 
Power Source: one 9V Battery

Products specifications
Attribute name Attribute value
Producer TES
Made in Taiwan
device type Portable
گارانتی One Year
current DC,AC :200μ /2m/20m/200m /200A A
Input Voltage AC/DC: 1000v , (AC): 200m/2/20/200/750v
Frequency MHz 20~Hz 10
Insulation resistance range 200/2K/20K/200K/2M/20MΩ