Search
Filters
Close

TES-5200 Particle counter

Particle mass Counter
Item Number:
Availability: Out of stock
Manufacturer: TES
709,200,000 ریال
ریال

particle mass counter,tes-5200

Optical system Triple 4 digit LCD display
Light source Laser diode
Laser product class Class 1, IEC 60825-1 / EN 60825-1
Sample flow rate 2.83L / min
Particle size (6 channels) 0.3μm, 0.5μm, 1.0μm, 2.0μm, 5.0μm, 10μm
Counting Efficiency 50% @0.3μm; 100% for particles >0.45μm (per JIS B9921:1997)
Relative Humidity ±7%, 20% to 90% non-condensing
Temperature ±3℃, 10℃ to 40℃ (50℉ to 104℉)
Maximum particle concentration 70,000 particles / L (coincidence loss max. 5%)
Measurement time 6s.(0.01CF), 21s.(1L), 1min.(0.1CF,2.83L)
3min.32s.(10L), 10min.(1CF,28.3L)
any length (MANUAL), any length (1s. to 59min.59s)
Buffer function Store and recall values for up to 500 measurements
PC interface USB interface
Tempersture / humidity measurable range 10℃ to 40℃, 20%RH to 90%RH (approximate)
Power requirements Built-in battery or AC adapter
Battery Rechargeable nickel metal hydride (Ni-MH) battery.
charged from supplied AC adapter when power is ON (charge time 2 hours).
AC adapter Input voltage: 100 to 240V AC, 50/60Hz
Dimensions and weight 212(L) x 120(W) x 60(H)mm / Approx. 930g
Supplied Accessories Users manual, AC adapter, USB connector, Carrying case.

particle mass counter,tes-5200

Optical system Triple 4 digit LCD display
Light source Laser diode
Laser product class Class 1, IEC 60825-1 / EN 60825-1
Sample flow rate 2.83L / min
Particle size (6 channels) 0.3μm, 0.5μm, 1.0μm, 2.0μm, 5.0μm, 10μm
Counting Efficiency 50% @0.3μm; 100% for particles >0.45μm (per JIS B9921:1997)
Relative Humidity ±7%, 20% to 90% non-condensing
Temperature ±3℃, 10℃ to 40℃ (50℉ to 104℉)
Maximum particle concentration 70,000 particles / L (coincidence loss max. 5%)
Measurement time 6s.(0.01CF), 21s.(1L), 1min.(0.1CF,2.83L)
3min.32s.(10L), 10min.(1CF,28.3L)
any length (MANUAL), any length (1s. to 59min.59s)
Buffer function Store and recall values for up to 500 measurements
PC interface USB interface
Tempersture / humidity measurable range 10℃ to 40℃, 20%RH to 90%RH (approximate)
Power requirements Built-in battery or AC adapter
Battery Rechargeable nickel metal hydride (Ni-MH) battery.
charged from supplied AC adapter when power is ON (charge time 2 hours).
AC adapter Input voltage: 100 to 240V AC, 50/60Hz
Dimensions and weight 212(L) x 120(W) x 60(H)mm / Approx. 930g
Supplied Accessories Users manual, AC adapter, USB connector, Carrying case.
Products specifications
Attribute name Attribute value
Producer TES
Made in Taiwan
device type Portable
گارانتی No warranty
رنج اندازه گیری ذرات 0.5µm ,0.7µm ,1.0µm ,2.5µm ,4.0µm ,5.0µm ,7.0µm ,10µm
رنج اندازه گیری غلظت ذرات 0~1000µg/cm3