Sort by
Position
Name: A to Z
Name: Z to A
Price: Low to High
Price: High to Low
Created on
Display
36
48
72
per page
SpO2 Measuring Range:70 - 99%
Pulse Rate range:30-235 bpm
SpO2 Measuring Range:70 - 100%
Pulse Rate range:30-235 bpm
SpO2 Measuring Range:70 - 99%
Pulse Rate range:30-235 bpm
SpO2 Range:70% - 100%
Pulse Rate Range:30 bpm - 235 bpm
SpO2 Range:70% - 100%
Pulse Rate Range:30 bpm - 250 bpm
Waterproof and washable
Big mucus cup
2sizes of silicone tips
with 3 types of nozzle for using in different conditions
White nozzle: 2mm large opening
Blue nozzle: 1mm smaller opening
Pink nozzle: 1mm narrower tip for newborns
use to suction remove nasal secretion and mucus in children
Large base design for easy grabbing and put down after use
Sensor Type:Thermopile
Display Temperature Range:0°C ~ 50°C
Operating Ambient Temperature:10°C ~ 40°C
Accuracy:± 0.2°C
Sensor Type:Thermopile
Display Temperature Range:0°C ~ 50°C
Operating Ambient Temperature:10°C ~ 40°C
Accuracy:± 0.2°C
Sensor Type:Thermopile
Display Temperature Range:0°C ~ 50°C
Operating Ambient Temperature:10°C ~ 40°C
Accuracy:± 0.2°C
Classic: 32.0°C ~ 43.9°C
Hypothermia: 26.0°C ~ 43.9°C
Classic: 32.0°C ~ 43.9°C
Hypothermia: 26.0°C ~ 43.9°C
2decimal-places digital thermometer
10memories
soft tip
Displayed Temperature Range 33°C ~ 44°C
Operating Ambient Temperature range 10°C ~ 40°C
Operating Ambient Humidity Range 0~95% RH
Accuracy ±0.2°C
Battery resistance:3 mΩ/30mΩ/300mΩ/3000mΩ
Voltage DC:6 V/60V/600V/1000V
Voltage AC:600 V
Voltage Range: 40V to 690V
Frequency Range: 15 to 400Hz
Nominal Test Current (per Phase): 1mA
MEASURE RANGE Pressure (mmHg) : 20 - 280
Pulse (beats/min) : 40 - 200
Pressure accuracy : ± 3mmHg
Pulse accurancy : ± 5%
MEASURE RANGE Pressure (mmHg) : 20 - 280
Pulse (beats/min) : 40 - 200
Pressure accuracy : ± 3mmHg
Pulse accurancy : ± 5%
MEASURE RANGE Pressure (mmHg) : 20 - 280
Pulse (beats/min) : 40 - 200
Pressure accuracy : ± 3mmHg
Pulse accurancy : ± 5%
MEASURE RANGE Pressure (mmHg) : 20 - 280
Pulse (beats/min) : 40 - 200
Pressure accuracy : ± 3mmHg
Pulse accurancy : ± 5%
MEASURE RANGE Pressure (mmHg) : 20 - 280
Pulse (beats/min) : 40 - 200
Pressure accuracy : ± 3mmHg
Pulse accurancy : ± 5%
One base station with one AC outlet supports up to six modules
Power supply 6V wall adaptor or four C-cell batteries
measuring range:20 ~ 600 mg/dL
Hematocrit Range:30% - 55%
0.5µL sample volume
measuring range:20 ~ 600 mg/dL
Accuracy:90% in zone A of EGA
Sample Volume:0.7 µL
measuring range:20 ~ 600 mg/dL
Sample Volume:0.7 µL
measuring range:20 ~ 600 mg/dL
Accuracy:90% in zone A of EGA
Sample Volume:0.7 µL
20 m /200 m /2 /20 /200 /2 K /20 K
4 terminal input, high accuracy.
Automatic timer with audible tone
Mixes in 8-12 seconds
3 customized memory presets
Automatic timer with audible tone
Mixes in 8-12 seconds
3 customized memory presets
Automatic timer with audible tone
Mixes in 8-12 seconds
3 customized memory presets
measuring range:20 ~ 600 mg/dL
Sample Volume:0.5 µL
Capillary action
Biosensor technology
Small blood sample
Test strips for cat
Capillary action
Biosensor technology
Small blood sample
Capillary action
Biosensor technology
Small blood sample
measuring range:20 ~ 600 mg/dL
Hematocrit Range:30% - 55%
0.5µL sample volume
measuring range:20 ~ 600 mg/dL
Hematocrit Range:30% - 55%
0.5µL sample volume
measuring range:20 ~ 600 mg/dL
Hematocrit Range:30% - 55%
0.5µL sample volume
Accessories for complete kit:
Conductivity cell(K=1.0).
Standard solution.
Distilled water.
9V Battery.
Instruction manual.
Gift box.
Optional: AC/DC adaptor.
Microprocessor based with splash proof housing.
Simultaneous display pH and Temperature.
Automatic or manual temperature compensation. °C/°F switchable
Simple to calibrate by one keyboard for 3 points buffer.
(Harmonics Analysis (V and I
50000 Records
Display of Overlapped Voltage and Current Waveform
Flue gas temperature range: -100 to +1250°C
Measure co: 0 to 8000ppm
Calculate co2 :0 to 99%
oxygen range: 0 to 21%
(PM2.5:0 - 500(ug/m3
Temperature (℃):0~2mg/m³
Vrms (AC+DC):1~1000 Vrms
TRMS currents up to 5000A
* Optional accessory for FORCE GAUGE, it is used to hold the tested materi
* 1500 g x 0.05 g, g/oz., high resolution.
* Auto self-calibration, counting function.
* Multi display unit, RS-232.
*5 start modes to activate logger recording (Immediate, Schedule, On-line, Magnetic, Repeat)
*Capturing Temperature data for multi-application
*Waterproof housing IP65 rating
*Logger is able to store & view current environment status
Clamp Meter
Diode Tester
Resistance 400Ω~40MΩ
Capacitance 4nF~200μF
AC Voltage Range: 40V-690V
Frequency Range: 15Hz~400Hz
AC Voltage Range: 70V-1000V
Frequency Range: 40Hz~70Hz
Non-Contact
Laser Infrared Thermometer
Temperature Gun
-
*The Digital Tachometer provides fast and accurate Contact and Non-Contact RPM and surface speed measurements of rotating objects.
* Measurement type: Rotation Speed (RPM,rpm), Total revolutions (REV), Frequency(HZ),Surface Speed(M/M,I/M,F/M,Y/M) and Length(M,In,FT,Yd).
* Wide measure range and high resolution.
Sensitive to 0.1 °C temperature changes
temperature range: from -20 to +250 °C
frequency:30 , 9 HZ
iP40 ABS housing
graphic display
IP66 remote solar cell
Digital display: 4 digits LCD.
Measuring level: 40~130 dBA, 40~130 dBC.
Resolution: 0.1dB.
Measuring range:0~1800µm
Accuracy:±3%H±1µm
(Resolution: 0.1µm (<100µm) or 1µm(>100µm
* Electromagnetic field tester.
* Range : 20/200/2,000 micro Tesla.
200/2000/20,000 milli-Gauss.
* Separate probe.
* Size : 163x70x30 mm.
Frequency: 10Hz~100KHz
DC Voltage: 400mV/4V/40V/300V
AC Voltage: 4V/40V/300V
Resistance: 400 ohm/4K ohm/40K ohm/400K ohm/4M ohm/40M ohm
Capacitance: 4nF/40nF/400nF/4uF/40uF/200uF
* Free chlorine, total Chlorine measurement.
* Range : 0 to 3.5 mg/L (ppm).
* Range : Auto range.
* Measuring principal : Photo meter method.
* Light source : LED, 525 nm.
(PM2.5:0 - 500(ug/m3
Temperature (℃):0~2mg/m³
Temperature - NTC range:-50 to +150 °C
Temperature - TC Type K:-200 to +1370 °C
Humidity - Capacitive range:0 to +100 %RH
Absolute Pressure:0 to 2000 hPa
Range:0-100% Volume content
Laser Target
Data Hold
MAX/MIN/AVG
Alarm set
Small pocket size
Tiny monitor
Reliable wide range of measuring
Light Alarm
DC and AC voltage:200mV/600V
AC and DC current:200μA/20A
Resistance:200Ω/20MΩ
Capacitance:.2000pF/20uF
Frequency:2KHz/10MHz
Inductance:20mH/20H
AC Voltage : 0-220mV~750V
DC Voltage : 0-220mV~1000V
AC/DC Current : 0-220µA~20A
capacitor:0-4000µF
Frequency:0~9.999MHz
Temp:- 50℃ ~ +400℃
Resistence:0~220MΩ
Max.display: 4000
Range selection: Auto ranging
Overload display: Display OL
Resistance:0-30MΩ
Capacitance:0-30mF
Measuring range:0~1800µm
Accuracy:± 3%H±1µm