Hydrogen Cyanide HCN-B1 Sensor
                            
                        
                            
                                Range: 100ppm HCN limit of performance warranty
 
Sensitivity: 80 to 140 nA/ppm in 30ppm HCN
  
Response time t90: < 120 (s) from zero to 30ppm HCN 
 
Resolution: < 0.05 RMS noise (ppm equivalent) 
                            
                        
                        
                        
                            
            
                Availability:
                Out of stock
            
        
     
                        
                        
            
                        
                        
                        
                            
                        
                            
                        
                        
                        
                        
                                                
                        
    
                        
                     
                        
                            Alphasense is expanding its line of electrochemical toxic gas sensors to address industry-specific requirements, including emissions monitoring, process safety, environmental monitoring and VOCs.HCN-B1 Hydrogen Cyanide Sensor price is available in sensotec website. 
| HCN-B1 Hydrogen Cyanide Sensor HCN Sensor PERFORMANCE | 
| Sensitivity | nA/ppm in 30ppm HCN | 80 to 140 | 
| Response time | t90 (s) from zero to 30ppm HCN | < 120 | 
| Zero current | ppm equivalent in zero air | < ±2.5 | 
| Resolution | RMS noise (ppm equivalent) | < 0.05 | 
| Range | ppm HCN limit of performance warranty | 100 | 
| Linearity | ppm error at full scale, linear at zero, 40ppm HCN | 0 to 4 | 
| Overgas limit | maximum ppm for stable response to gas pulse | 200 | 
| HCN-B1 Hydrogen Cyanide Sensor HCN Sensor KEY SPECIFICATIONS | 
| Temperature range | °C | -30 to 50 | 
| Pressure range | kPa | 80 to 120 | 
| Humidity range | % rh continuous | 15 to 90 | 
| Storage period | months @ 3 to 20℃ (stored in original container) | 6 | 
| Load resistor | Ω (recommended) | 10 to 33 | 
| Bias voltage | V | not required | 
| Weight | g | < 6 |