Sort by
Display
per page
For remote control of fan coil unit thermostats
:QBE3000-D different models
QBE3000-D1,QBE3000-D1.6,QBE3000-D2.5
QBE3000-D4,QBE3000-D6,QBE3000-D10,QBE3000-D16
Sensor:PT1000, class A
Accuracy: ≤±0.5°C
2year Warranty
Adjusting range of temperature:6-28 celsius
1mA test current for MegOhm range
200mA short current for continuity range
(Measuring range 0 to +60 °C (Short-term to +80 °C max. 5 min
Accuracy ±0.4 °C
Resolution 0.1 °C
Measuring range 1 to 99999 rpm
Accuracy ±0.02 % of mv
Resolution 0.01 rpm (1 to 99.99 rpm)
0.1 rpm (100 to 999.9 rpm)
1 rpm (1000 to 99999 rpm)
2year Warranty
operating range:0-40C
differential:1.5C
Ferrous metals 80mm
Non-ferrous metals 80mm
Live Conductors 50mm
fequency ranges:
9 ,30 Hz
temperature range:
-4 - 482°F
Thermal sensitivity ≤ 0.10°C
NTC probe :-40 to +120 °C
temperature range: -40 +70 °C
capacity: 20,000 points
Record power and parameters up to 45 days
with IP65 case, 600 V CAT III
Measure all three phases and neutral
with included 4 flexible current probes
Noise (A Weighting):30~130dB
Resolution:0.1dB
Frequency response:31.5Hz~8kHz
* -P circuit, LCD with display unit.
* Max., Min., Memory recall button.
* 200uS/2mS/20mS, ATC, Cell adj.
* Size : 180 x 72 x 32 mm.
Measuring range CO :0~500 ppm
CO measurement range : 0 to 500ppm
Measuring range CO :0~500 ppm
CO range : 0 to 1,000 ppm
Measuring range 0 to +1999 ppm
Measuring range CO :0~999 ppm
Measuring range CO2:0 to +10000 ppm
Light Measuring range:0 to 100000 Lux
temperature measuring range with different probes
Earth Ground Resistance:0/20/200/2000Ω
EARTH VOLTAGE:200V
Earth Ground Resistance:0/20/200/2000Ω
Earth Voltage:0~30V
Resolution:0.01Ω
Earth Ground Resistance:0/20/200/2000Ω
Earth Voltage:0~30V
Resolution:0.01Ω
earth resistance:0 to 1600Ω
Measure leak current with 0.01 mA resolution
Measure load current up to 60A
earth resistance:0 to 1600Ω
Measure leak current with 0.01 mA resolution
Measure load current up to 60A
earth resistance measurement 0 to 20.99kΩ
soil resistivity measurement 0 to 395.6kΩm
Earth Ground:0/10/100/1000Ω
Earth Voltage 0~30V
Earth Ground:0/10/100/1000Ω
Earth Ground:0/10/100/1000Ω
Earth Voltage 0~30V
earth resistance:0 to 2000Ω
Earth voltage:0 to 30.0 Vrms
Earth Ground Resistance:0.01-1000Ω
Resolution:0.01Ω
Earth Ground Resistance:0.01-1000Ω
Resolution:0.01Ω
detects smoke and smakeable firing
power supply:220v
with alarm
Earth Resistanc:0~20/200/2000Ω
Testing Voltage:250/500/1000V
Insulation Resistance:0.1~2000MΩ
Operating voltage:DC 8…33 V
Output signal:4-20mA
QBM3120-25 Pressure range:0-2500Pa
Measurement Range:0 to 1000PPM
Measurement Resolution:1PPM
Accuracy:±5% or ±10PPM
Detection of gas: air, carbon monoxide
Measuring range: 0 ~ 1000ppm
Resolution: 1ppm
Response time: 60 seconds
Sensor Type: Electrochemical CO sensor
Rated voltage: 500V / 1000V / 2500V / 5000V
Measuring range:5000V: 0.0~1000Gohm
Max. short current: 1.4mA
Input voltage range:3V~9V
Current monitoring range:0~3A
Energy 0-9999mAh
Input voltage range:3V~9V
Current monitoring range:0~3.5A
Capacity:0~39999mAH
Voltage range 4~24VDC
Current range (Type-C) 0.05~5ADC
Capacity 0~99999mAh
Energy 0~1000Wh
Sensors protected with pump auto stop
Self test menu
Sensor O2 from 0 - 21 percent
sensor CO-H2 from 0 - 8000 parts per million
Step by step procedure
Sensor protection with pump stopping
Auto diagnostic menu
* Kits with pH METER, soil pH electrode, pH 4.0/pH 7.0 standard solution, carrying case.
* Meter : 0 to 14 pH x 0.01 pH. Electrode : 1 to 13 pH.
* Pocket housing, LCD display.
Capture and analyze nuisance tripping
from 3 to 300 seconds
measurement AC/DC current:
of AC current up to 1400A rms
and DC current up to 2000A
Measuring range 30 to 12500 rpm
Accuracy ±0.01 % of mv
Resolution 1 rpm
temperature measurement up to 1200 °C
Capture up to 5 additional measurements
Voltage range 4~24VDC
Current range (Type-A) 0.05~3ADC
USB data cable voltage (D+, D-) 0~3.3V
Voltage range 4~24VDC
Current range (Type-A) 0.05~3ADC
USB data cable voltage (D+, D-) 0~3.3V
Up to 8192 storage points
Measuring range: -40 to +85°C
IP 67 casing
temperature range:-40 +70 °C
NTC probes CTN : -40 to +120 °C
IP65 housing
Sound level Range:30 to 130dB
Frequency weighting: A/C
32000 Reading Internal Memory
Measuring range: -500 to +500 mbar
0.1 mbar resolution
* Wide ranges conductivity meter
* 4 ranges : 200 uS, 2 ms, 20 mS, 200 mS.
* 4 rings conductivity probe, high performance.
* Data hold.
flat surface probe
measuring range:-50-750°C
Measuring range CO2:0 to +10000 ppm
temperature measuring range with different probes
Bandwidth: 100MHz
Sampling rate up to 1Gsa/s & 500Msa/s
Max. input voltage 400V (peak)
Measurement range:0.04 to 3.2% vol
Product Number: 004-0-0061
Digital temperature sensor
Accuracy: ≤±0.5°C@0~85°C
Digital temperature sensor
Accuracy: ≤±0.5°C@0~85°C
Digital temperature sensor
Accuracy: ≤±0.5°C@0~85°C
Digital temperature sensor
Accuracy: ≤±0.5°C@0~85°C
TT6N Series Temperature Sensor/Transmitter
Accuracy: ≤±0.5°C@0~85°C
Digital temperature sensor
Accuracy: ≤±0.5°C@0~85°C
Digital temperature sensor
Accuracy: ≤±0.5°C@0~85°C
Digital temperature sensor
Accuracy: ≤±0.5°C@0~85°C
Digital temperature sensor
Accuracy: ≤±0.5°C@0~85°C
Digital temperature sensor
Accuracy: ≤±0.5°C@0~85°C
Digital temperature sensor
Accuracy: ≤±0.5°C@0~85°C