Sort by
Display
per page
Temperature range:-50 to +150 °C
Pressure Measuring range:-1 to 60 bar
Vacuum Measuring range:-1 to 0 bar
Temperature range:-50 to +150 °C
Pressure Measuring range:-1 to 60 bar
Vacuum Measuring range:0 to 20000 micron
Absolute Pressure:0 to 26.66 mbar/0 to 20000 micron
Accuracy:± 10 micron + 10 % of mv
Testing Voltage:AC 230V±10% or AC 110V±10%
Frequency:50-60Hz
Detection as precise as 0.00046%
Five alarm levels and two sensitivity modes
One device protections up to 8,000 sq. feet
Nuisance-free Technology
photoelectric smoke sensor
Smoke alarm Red LED
Service alarm:
Red LED on detector
Yellow LED on control unit
Smoke alarm Red LED
Service alarm:
Red LED on detector
Yellow LED on control unit
Smoke alarm Red LED
Service alarm:
Red LED on detector
Yellow LED on control unit
Measuring range
Ra: 0.05-10.0μ Rz: 0.1-50μ
Measuring range
Ra: 0.05-10.0μ Rz: 0.1-50μ
Measuring range
Ra: 0.025-12.5μ
Scanning Range:2.5mm~9999mm
Gain Range:0dB~110dB
Two scanning modes: A scan and B scan
Range: 0~199.9 Gu
Angle: Single 60 degrees
Ray types:α, ß, γ and X ray
Radiation dose rate : 0.01µSv/h - 1000µSv/h
Pulse dose rate : 0-4000cpm, 0-4000cps
Detection range: 0 ~1.500mg/L
Resolution:0.001mg/L
Accuracy:C<0.400 : ±0.020mg/L
Measuring range: ±10kPa
Accuracy: ±0.3%FSO
Measuring range: ±10kPa
Accuracy: ±0.3%FSO
Measuring range: ±350kPa
Accuracy: ±0.3%FSO
accurancy
CO2: ±40 ppm + 2 % of reading
DC model: 75 ppm or 10 % of reading
Temperature: <0.5 °C
accurancy
CO2: ±40 ppm + 2 % of reading
DC model: 75 ppm or 10 % of reading
Temperature: <0.5 °C
Refrigeration power: Qcmax 70.3W
Maximum temperature difference:60 C
Leads length: 900mm
Rod length: 115mm
Tip length: 18mm
Connects to PC via USB or Ethernet to download data
Easy setup with a network or USB drive
External Interface:1 USB port,1 Ethernet port
RS-485 Modbus communication interface.
3 DPDT relay outputs for added functionality
Easy chain installation RS-485
Fully compatible with the 301C controller
Power requirement: 17-24 VAC, 24-38 VDC, 250 mA
Min. air flow:1.0 m/s (not trimmed) or 2.5 m/s trimmed
Max. air flow:8 m/s (not trimmed) or 9.2 m/s trimmed
Fits pipe sizes ranging from ½” to 8”
Infrared sensor Dual element
with a 110°,15m detection range.
Infrared sensor Dual element
Mounting height:2.4-4.2 m
360° detection
Covers an area up to 8 meters in diameter
Detection range 12 m over 110° angle
2m mounting height
Communication range Up to 300 m
1.5mm diameter holes
at 20%, 40%, 60% and 80% of thickness.
Tolerance of 0.0004 inch
1.5mm diameter holes
at 20%, 40%, 60% and 80% of thickness.
Tolerance of 0.0004 inch
Ultrasonic Calibration Blocks
Clibration Block for flaw detector
thickness gauge test block
Ultrasonic Calibration Blocks
Clibration Block for flaw detector
thickness gauge test block
مطابقت با استاندارد ATSM E 2491
ضخامت 25 mm
Range:0-1500µm
accuracy:±1% or ±1µm
Range:5-80mm
diameter:12mm
Frequency:5MHz
Frequency:2MHZ,4MHz
Angles;45,60,70
Range:1.2-225mm
diameter:10mm
Frequency:5MHz
Range:0.75-60mm
diameter:6mm
Frequency:7MHz
Range:0-1500µm
accuracy:±1% or ±1µm
Range:1.2-225mm
diameter:10mm
Frequency:5MHz
Frequency:2MHZ,4MHz,6MHz
diameter:10mm,20mm
یک عدد بلوک از جنس فولاد کربنی ST37
دارای عیوب بسیار ظریف سطحی و زیرسطحی، برای تست DC و AC
یک عدد بلوک آلومینیومی ۱۰ در ۲۰ سانت و ضخامت ۱ سانت
دارای عیوب متعدد برای تست PT
جنس بلوک : فولاد ضد زنگ
روش جوشکاری : کلیه روش های قوسی
Ultrasonic Calibration Blocks
Clibration Block for flaw detector
thickness gauge test block
Shims thicknesses from 12.5μm to 20mm
Cable for Ultrasonic Flaw detector
BNC Lemo Connector