Measuring range, temperature -30…+50 °C
CP111 : from -100 to +100 Pa with EV
CP112 : from -1000 to +1000 Pa
CP113 : from -10 000 to +10 000 Pa
CP114 : from -500 to +500 mbar
CP115 : from -2000 to +2000 mbar
temp range:-4 - 482°F
80*60 resolution
measuring ranges:
with optical :rpm 600000 to 60
contact probe: rpm 20000 to 30
Pt100 remote probe: -100 to +400 °C
2-line display
20,000 measuring points
logging up to 500 power parameters
with the IP65
IEC61000-4-30 Class-A compliant
voltage accuracy 0.1-Percent
Frequency analytics from 63 to 8 kHZ
2 channel measurement
Measurement range
-50°C to 700°C ; -58°F to 1292°F
Probe Length: 150mm
-35 ºC ~ 500 ºC
Built-in Laser Targeting
Backlight LCD display
MAX / MIN function
T1N Series Temperature Sensor
Accuracy:±0.2~0.4°C@25°C
T2 Series Temperature Sensor
Accuracy:±0.2~0.4°C@25°C
T2N Series Temperature Sensor
Accuracy:±0.2~0.4°C@25°C
T4 Series Temperature Sensor
Accuracy:±0.2~0.4°C@25°C
T4N Series Temperature Sensor
Accuracy:±0.2~0.4°C@25°C
T5 Series Temperature Sensor
Accuracy:±0.2~0.4°C@25°C
T6 Series Temperature Sensor
Accuracy:±0.2~0.4°C@25°C
Depth Range
Wooden Stud / Metal Beam: Up to 4cm
Iron/Solid Bar: Up to 10cm
Copper / Water Pipe: Up to 5cm
Live Voltage: Up to 4cm
Insulation resistance:100/4000MΩ
testing voltage:250/500V/1000 V
Measuring range CO2:0 to +10000 ppm
Light Measuring range:0 to 100000 Lux
temperature measuring range with different probes
NiMH Battery operating time of 6.5 hours
Calculates 3-phase power on balanced loads
As a millimeter and scope
Test Voltages of 500V, 1000V, 2500V, and 5000V
Measure Insulation Resistance to 60G
Insulation resistance up to 10 TΩ
Test voltage:250V-5kV DC
insulation resistance up to 100MΩ
Single range testing voltage of 500 V
insulation resistance up to 1000 MΩ
Single range testing voltage of 500 V
insulation resistance up to 2000 MΩ
Single range testing voltage of 1000 V
Insulation resistance:100/250/500/2000/4000MΩ
Rated output voltage:50/125/250/500/1000V
Insulation resistance:100/250/500/2000/4000MΩ
Rated output voltage:50/125/250/500/1000V
Insulation resistance:100/250/500/2000/4000MΩ
Rated output voltage:50/125/250/500/1000V
Insulation resistance:100/250/500/2000/4000MΩ
Rated output voltage:50/125/250/500/1000V
insulation resistance up to 4000MΩ
test voltage up to 1000 V
with 1 V resolution
7LED array – 4,800 Lux -6,000 FPM/30cm
high accuracy : 0.02%
higher flash rates – 30-300,000 FPM
measuring ranges:
Thermocouple K :-200 to + 1000 °C
Thermocouple J :-100 to + 750 °C
Thermocouple T :-200 to + 400°C
Thermocouple S :0 to + 1760 °C
100,000 measurement points
measuring range: -58 to 572 degrees
resistance temperature detectors
platinum wire
acoustic pressure level :
at 94 dB with a 1000 Hertz frequency
From -500 to + 1000 Pa
IP 65
℃ / ℉ K Selectable.
Laser targeting.
Maximum / Minimum function.
Data memory and read function.
Back-light LCD display.
Sensor:PT1000, class A
Accuracy: ≤±0.5°C
Measuring range, temperature 0…50 °C
Sensor element, temperature NTC
Accuracy, temperature ±0.5 K
Supply voltage 230 V AC
Change-over contact for control of heating or cooling
Contact rating 16 A, 250 V
Two-position control
Switching voltage AC 24…250 V
2-position control
Manual 3-speed fan switch
Switching voltage AC 250 V
for 2-pipe, 2-pipe with el. heater and 4-pipe fan coil units
for use with compressors in DX type equipment
for 2-pipe, 2-pipe with el. heater and 4-pipe fan coil units
for use with compressors in DX type equipment
2year Warranty
temperature control range:10-35C
2year Warranty
different temperature range
0-35C,0-60C
2year Warranty
temperature control range:10-30C
2year Warranty
temperature control range:10-30C
2year Warranty
temperature control range:10-30C
مجهز به صفحه نمایش LCD بزرگ
Setpoint range 0...40°C
Closing relay 13 A, 230 V
One stage
closing relay contact,16 A, 230 V AC
Supply voltage 230 V or 24 V AC
2stage in sequence or binary
Settable control of either heating or cooling
2year Warranty
Fixed set-point thermostat
single-polesnap action contact
2year Warranty
Operating range:5-45,0-90,0120 Celsius
2year Warranty
Operating range:5-45, 0-90, 0-120 celsius
2year Warranty
operating range:5-45C,0-90C
0-120C,50-290C
2year Warranty
two method for installation
mounted in series
mounted in parallel
2year Warranty
Operating range:
5-45C,0-90C,0-120C
with different temprature :
30-90C
30-120C
50-300C
with different tempratuers :
-30-+30C
30-90C
30-120C
50-300C
2year Warranty
SPST contact
SPDT contact
2year Warranty
SPST contact
SPDT contact
2year Warranty
SPST contact
SPST contact
2year Warranty
Operating range:5-45,0-90,0120 Celsius
2year Warranty
Operating range:
5-45C,0-90C,0-120C
Sensor element Liquid-filled copper bulb
Bulb dimensions Ø 9.5
Capillary length 1.5 m
Dust-tight microswitches with SPDT contacts
Temperature range -10...+10˚C
Contacts SPDT microswitch
Switch capacity 15 (8) A, 24...250 V AC
Accuracy ± 1°K
Gas-filled copper sensor element
with a 1.8 m, 3 m or 6 m long capillary tube
Temperature range:7-30°C
Contacts NO/NC 250 V AC 16 (2.5) A