output voltage:50V/100V/250V/500V/1000V
Insulation Resistance:0.01MΩ~20GΩ
Short Circuit Current<2mA
DC/AC Voltage (V):0.0V~600.0V
temp range:-20°C to +850°C
Filter Mode: ≤0.04°C at 40°C target temp
* Humidity range : 10 % to 95 % R.H.
* Temp. range : 0 oC to 50 oC,32 oF to 122 oF.
* 0.01 %RH, 0.01 degree.
*Digital display with analog graph
*Auto / Manual ranging
*Max Hold, F/S response, A/C Weighting
*Analog output
OPC-N3 measure from clean rooms
to pollution levels of 2,000 μg/m3 (PM2.5)
Measuring range 0 to 20000 ppm
Lower response threshold 100 ppm
1st alarm limit 10000 ppm (20% LEL)
Measuring range CO2:0~9999 ppm
Measuring range CO :0~1000 ppm
Four measuring ranges
measuring differential pressure
in air and non-corrosive gases
LED Display
Frequency Output:10 MHz
Sample rate : 125MS/s
Temperature range -50...+110°C
Sensor element PT1000, 1000 Ω/0°C
Cable length 1.5 m
Protection class IP65
Time constant 18 s
Measuring range, temperature -20...+120 °C
Protection class IP65
Measuring range, temperature -20...+75°C
Temperature range 0-50°C
Sensor element PT100, 100 Ω/0°C, DIN class B
Protection class IP30
Differential pressure range 0 ... 4 bar
Accuracy:
NTC10k ± 0.25 °C
NTC20k ± 0.25 °C
Pt1000 ± 0.3°C
Ni1000 ± 0.4 °C
Automatic 8, 10 and 12 fiber measurements
Troubleshoot MPO fiber links
* Real time data recorder, save the data into the SD memory card and can be download to the
Excel, extra software is no need.
* pH : 0 to 14.00 pH.
* mV (ORP) : -1999 mV to 1999 mV.
* Manual temperature compensation.
a 1000-count digital RCD tester
Over-range display
With phase switch
connections check
AUTO RAMP
Measuring resistance 0.01Ω ~ 1000Ω
AC True RMS leakage current at 0 ~ 30A
* Photo Tach. : 5 to 100,000 RPM
* Contact Tach. : 0.5 to 19,999 RPM.
Surface speed : m/min, ft/min.
200GΩ insulation resistance tester
output voltage:50V/100V/250V/500V/1000V
Short Circuit Current<2mA
Leakage Current:10 ~ 2000μA
temp measuring range:-4 - 2192°F
Thermal sensitivity ≤ 0.045°C @ 30°C target temperature
Measuring range: 0 to +125°C
memory capacity :Up to 8192 points
2 alarm setpoints
logging up to 500 parameter
with EN50160 power quality standard
IEC61000-4-30 Class-A voltage accuracy
* Humidity meter/%RH : 10 to 95 %RH.
* Humidity meter/Temp. : 0 to 50.0 oC, oC/oF.
* Type K Thermometer : -50 oC to 1300 oC.
Measuring range : 30-130 dB
Resolution : 0,1 dB
brand:ariak
model:ASZ-220B
smoke detector ariak series ASZ
Measurement range CO2: 0 to 3%vol
Product Number: 030-7-0001
Frequency Output:25 MHz
Sample rate : 125MS/s
RAK different models:
RAK-TR.1000B-H,RAK-TR.1000S-H,RAK-TR.1210B-H
QAF81... different models are followed as:
QAF81.3,QAF81.6,QAF81.6M
Strap-on Thermostats:RAM-TR, RAM-TW
Switch-over contact AC 250 V / 10(2) A
Measuring range 20 ...110 °C
:QBE63-DP different models
QBE63-DP01,QBE63-DP02,QBE63-DP05,QBE63-DP1
Accuracy:
NTC10k ± 0.25 °C
NTC20k ± 0.25 °C
Pt1000 ± 0.3°C
Ni1000 ± 0.4 °C
QAM21... different models are followed as:
QAM2110.040,2112.040,2112.200
QAM2120.600Q,AM2120.040,QAM2120.200
QAM2130.040,QAM2140.020
QAA... different models are followed as:
QAA24,QAA25,QAA26,QAA27
setting range 5...35 °C
Range of use 0...50 °C
Sensing element LG-Ni 1000
QAD2... Strap-on temperature sensor different models:
QAD22,QAD2010,QAD2012,QAD2030,FA-T1G
QAE21... different models:
QAE2110.010,QAE2110.015,QAE2111.010,QAE2111.015
QAE2112.010,QAE2112.015,AE2120.010,QAE2120.015
QAE2121.010,QAE2121.015,QAE2122.013
QAE2130.010,QAE2130.015,QAE2140.010
Accuracy:
NTC10k ± 0.25 °C
NTC20k ± 0.25 °C
Pt1000 ± 0.3°C
Ni1000 ± 0.4 °C
QAC... Outside Sensors different models:
QAC22,QAC32,QAC2010,QAC2012,QAC2030,FW-T1G
QFM21... models:
QFM2100,2101,2120
QFM2140,2160,2171
Setting range nominal setpoint 0…50 °C
with 2 analog control outputs DC 0…10 V
for heating and/or cooling
Setting range nominal setpoint 8…30 °C
with 2 analog control outputs DC 0…10 V
for heating and/or cooling
Hunt signal transmission distance:> 1Km
Hunt signal transmission distance:> 1Km
Voltage Measuring Ranges 12V, 50V, 120V, 230V, 400V
Freqnecy Range:0 to 60Hz
Tracing Depth cable location:0 - 2.5m
Main Voltage Detection:0 - 0.4m
:Resistance range
at Low Power OFF:100 mΩ-100 MΩ
at Low Power ON 1000 mΩ -1000 Ω
:Resistance range
at Low Power OFF:100 mΩ-100 MΩ
at Low Power ON 1000 mΩ -1000 Ω
Resistance range:10 mΩ to 1000 Ω
Resistance range:30mΩ -3MΩ
Testing current:
at 30 mΩ range 300 mA DC
at 3 MΩ range 500 nA DC
:Resistance range
at Low Power OFF:10mΩ-1000 MΩ
at Low Power ON 1000 mΩ -1000 Ω
:Resistance range:3 mΩ-3 MΩ
Temperature range:-10.0 to 99.9°C
Insulation test range:0.1 MΩ to 2000 MΩ
Insulation test voltages:500 V, 1000 V
AC/DC voltage from 0.1 V to 600 V
* pH : 0 to 14.00 pH, mV : -1999 to 1999 mV, Temp. : 0 to 100.0 oC.
* Manual/Auto Temp. compensation.
* Size : 160 x 80 x 35 mm.
( Phase angle selection (0°and 180°
1A trigger test
AUTO RAMP measurement
Measurement Range:-70dBm~+10dBm
Wavelength Range:800nm-1700nm
Universal connector FC/SC/ST
Detector Type InGaAs
Measurement Range:-50dBm~+26dBm
Wavelength Range:800nm-1700nm
Universal connector FC/SC/ST
Detector Type InGaAs
Measurement Range:-70dBm~+10dBm
Wavelength Range:800nm-1700nm
Universal connector FC/SC/ST
Detector Type InGaAs
measuring ranges:
with optical :rpm 600000 to 60
contact probe: rpm 20000 to 30
logging up to 500 power parameters
with the IP65
with the IEC61000-4-30 Class-A compliant
voltage accuracy 0.1-Percent.
Wire types:Telephone line\twisted-pair\electric wire
Telephone lines tracking distance≥3000m
Audio signal test range ≥1000m
Video line distance ≥100m
Noise exposure
Detection and peak counting
:QBE61.3-DP different models
QBE61.3-DP2,QBE61.3-DP5,QBE61.3-DP10
Minimum Range:
pair cable or coaxial cable>5m
Single cable>10m
Accuracy:
±(2% of reading + 10cm)<100m
±[2% of reading +20cm]≥100m
Density: 0 g/cm³ to 3 g/cm³
Temperature: 0 °C to 40 °C
Density: 0 g/cm³ to 3 g/cm³
Temperature: 0 °C to 40 °C
Measuring range, temperature -40…+50 °C
Measuring range, temperature (PT1000) -50…+75 °C