Fits pipe sizes ranging from ½” to 8”
Measure volts, mA, RTDs
thermocouples, frequency, and ohms
easy to operation and carry
Memory storage for up to 8 calibration results
HART mode inserts 250 ohm resistor in mA measure
Measure or source pressure
using any of 29 Fluke 700Pxx Pressure Modules
Measuring range -20 to +70 °C
Accuracy ±0.5 °C (-20 to +70 °C
Resolution 0.1 °C
for calibrating, maintaining, and troubleshooting
dual display
Rechargeable Li-Ion battery
* Type k thermocouple calibrator.
* Type k thermocouple thermometer.
* -199 oC to 1230 oC, -325oF to 2246oF.
* Resolution : 0.1 oC ( <1000 oC ).
(Compatible with pulsed RTD transmitters (pulses > 10ms
ºF or ºC selectable
Measure temperature from TC output
Simulate TC output
Selectable ºF or ºC
source 10 thermocouple types and 7 RTD types
The dual line measure/source display
Measure RTDs, thermocouples, ohms, and volts
* Professional, 1 KHz.
* Die casting aluminum alloy housing case.
* DC 9V batteries x 2 PCs.
* Size : round 50 mm Dia. x 82 mm.
Measure or generate 4 to 20 mA
Measure 0 to 30 V DC
generate pressures from vacuum to 2 MPa
pump can generate vacuum to -80 kPa
Measure pressure with internal sensor up to 345 bar sensor
Measure mA with 0.015% accuracy and 0.001 mA resolution
Measure pressure to 700 bar
using one of 29 Fluke 700Pxx Pressure Modules
30,100and 300 psi ranges
Pressure measurement to 0.05% of full span
Current measurement with 0.02% accuracy
and 0.001 mA resolution
Fluke 719 30G Range: -12 to 36 PSI
Fluke 719 100G Range: -12 to 120 PSI
Resolution: 0.01 PSI
Accuracy: up to 0.025%
:pressure ranges
30psi and 100 psi
mA signals to troubleshoot 4-20 mA loops
Power transmitters using 24 V loop supply
Measures 4 to 20 mA signals
Measure up to 30 V DC
check 24 V loop power supplier
mA sourcing, simulation and measurement
0.02% accuracy and 0.001 mA resolution
0-28:VDC measurement
Current range:0to 24 mA
0.015% accuracy
resolution: 0.001 mA
Measures V DC to 28 V
0.015%mA accuracy of
1µA resolution for mA source
Push button with 25% steps for fast
Measures Vdc to 28 V
Temperature Range:50 to 500°C
Target Size: 57m
Certify IR pyrometers from :–30°C to 500°C
target:Large 57 mm
* Current source : 0 to 24 mA, 2 ranges.
* Current measurement : 0 to 24 mA, 2 ranges.
* Power (12 V) and current measurement of two wire loop : 0 to 24 mA, 2 ranges.
* DC mV source : -199.9mV to +199.9mV.
Voltage AC:400V/750V
Current AC:400/600A
Resistance:4000Ω
AC/DC Voltage up to 600V
AC Current up to 150A
Resistance up to 40Mohm
Capacitance up to 40mF
Temperature:-20°C~1000°C
AC Current:2mA/20mA/60A
Resolution:0.001mA/0.01mA/0.1A
AC/DC Voltage up to 600V
AC Current up to 200A
Resistance up to 20Mohm
Temperature:-20°C~1000°C
AC/DC Voltage up to 600V
AC Current up to 600A
Resistance up to 40Mohm
Capacitance up to 100uF
Frequency up to 100KHz
Temperature:-20°C~1000°C
Controller for heating and boiler control in buildings
controller for both simple
and advanced ventilation applications
control of air handling units with temperature control
Handles humidity control
Controllers for heating and boiler control
supply voltage 24 V AC / DC
Compact controllers for heating and boiler control
Supply voltage:230V AC
7integrated relay outputs
Equipped with three serial ports and one TCP/IP port
Optigo OP10 is a pre-programmed controller
OP10 has 10 in-/outputs
OP10 is available in two models
OP10 with 24 V AC supply voltage
OP10-230 with 230 V AC supply voltage
%Supply voltage:24 V AC ±15
OP5U has 5 in-/outputs
Controller for control of temperature, CO2 and pressure
Electric heating controller
for external input signal 0-10 V
230V AC or 400 VAC
Controller with PI-control,230-400V AC
For loads up to 3.6 kW-230 V or 6.4 kW-400 V
Controller with PI-control,230-400V AC
For loads up to 3.6 kW-230 V or 6.4 kW-400 V
climate control in public buildings
can be used in systems with communication
EXOline (over RS485 or TCP/IP), Modbus (RS485) or LON
Load up to 13 A 230 V AC
Setpoint 1..10 corresponding to 10…100%
with built-in sensor and 0...10V output
for control of heating or cooling in HVAC systems
Ambient temperature:
Sensor -20...70°C
Housing -20...60°C
Cable gland PG11
Ambient temperature:-20-40°C
Setpoint:10-95% RH
Hysteresis:4%RH at 45%RH
Ambient temperature 0…40°C
Setpoint (humidity) 35…95% RH
Hysteresis 7% RH
Supply voltage:3-phase, 210...255V / 380...415V AC
PI-control for supply air control
P-control for room control
Supply voltage:3-phase, 210...255V / 380...415V AC
Supply voltage:3-phase, 210...255V / 380...415V AC
20-segment calibrated bar graph
toxic, Oxygen, combustible gases sensors
connect up to 96 transmitters in three loops
RS-485 communication protocol
A full complement of sensors including:
toxic, Oxygen, combustible gases and refrigerant sensors
Combine with 301IRF and S301D2 sensors
Accepts inputs from
up to two 4-20mA sensors transmitters
Accepts inputs from
up to two 4-20mA sensors transmitters
Display:320 x 240 LCD with backlight
Power:10 – 30 VDC,12 Watts max
Operating temperature:-25°C to +60°
Supports Honeywell gas sensors including
NH3, CO2, H2, CO, Cl2, CFC’s, HCFC’s
HFC’s, CH4, O2, NO2, and more
Zoning capability allows for up to 126 zones
TS35 (‘top hat’) DIN rail mounting
Compatible with a wide range of gas detectors
3 wire mV bridge, 2 and 3 wire 4-20mA inputs
Display: 128 x 64 pixel graphic LCD
Power requirement: 100-240 VAC / 24 VDC
Operating temperature: -25°C to +50°C
Nut insertion length:
28mm long,45mm long,55mm long
Range of Measurement:
0.1to 25% O₂
0.1to 100% O₂
80mm probe,220mm probe,600mm probe
Range of Measurement:
0.1to 25% O₂
0.1to 100% O₂
Digital Humidity & temprature
item number:3006
Digital Humidity & temprature
item number:3005
Digital Humidity & temprature
item number:3007
Range of Measurement: 0 to 100%
Output Range: 10 to 15.5 mV
Range of Measurement:
0to 25% O2 0 to 300mbar ppO2
Temperature Range: -30 to 60⁰C
Range of Measurement:
0to 25% O2 0 to 300mbar ppO2
Temperature Range: -30 to 60⁰C