Sort by
Position
Name: A to Z
Name: Z to A
Price: Low to High
Price: High to Low
Created on
Display
36
48
72
per page
light meter
Item Number:
light.rang:20/200/2000/20000LUX
light meter
Item Number:
light.rang:0.01Lux~999900Lux
Voltage DC:320m/3.2/32/1000V
Voltage AC:3.2/32/320/750V
Current:µ320 /3.2m/32m/320m/20A
resistance:320/3.2k/32k/320k/3.2M/30MΩ
DC/AC current:4m/40m/400m/20A
DC Voltage: 400m/4/40/400/1000v
AC Voltage: 400m/4/40/400/750v
Resistance:400/4K/40K/400K/4M/40MΩ
Frequency:100/1K/10K/100K/500KHZ
DC/AC current to 10A
DC/AC Voltage to 1000V
Resistance to 50MΩ
Frequency to 10MHZ
capacitance to 10mF
Adjusting sound alarm rate
LED alarm
Automatically reset
Measuring range:14° to 140 °F / -10 to +60 °C
Accuracy:±0.7 °F / ±0.4 °C
Measuring range:0 to 100 %rH
Measuring range 0 to +50 °C -20 to +50 °Ctd
Accuracy ±0.5 °C (at +25 °C
Resolution 0.1 °C
light meter
Item Number:
light.rang:20/200/2000/20000 Lux
light meter
Item Number:
light.rang:0.1lux ~200/2000/20000/200000 lux
noise dosimeters
Item Number:
Measurement range: 70 ~ 140dBA
noise dosimeters
Item Number:
Measurement range: 70 ~ 140dBA
CHROMA METER
Item Number:
Auto ranging 0.1lx ~ 99990lx
Range: 100ppm NH3 limit of performance warranty
Sensitivity: 25 to 45nA/ppm in 50ppm NH3
Response time t90: <60 (s) from zero to 50ppm NH3
Sensitivity: -225 to -550 nA/ppm at 1ppm O3
Sensitivity: -250 to -650 nA/ppm at 2ppm NO2
Response time: < 45s from zero to 1ppm O3
Range: 20 ppm O3/NO2 limit of performance warranty
Temperature range: -30 to 40 ℃
Pressure range: 80 to 120 kPa
Humidity range: 15 to 85 % rh
Output: 80 to 120 μA @ 20.9% O2
Response time t90: < 15 (s) from 20.9% to 0% O2
Diameter: 20.0 mm (including label)
Height: 17.4 mm (including foam ring)
Range: 50ppm limit of performance warranty
Sensitivity: 320 to 480 nA/ppm at 2ppm SO2
Response time t90: < 20 (s) from zero to 2ppm SO2
Frequency Output : 5 MHz
Sample rate : 125MS/s
Measuring range:0~9999 ppm
Display- digit: 1999
Resistance : 20Ω -- 2000MΩ
Capacitance : 2000pF -- 200μF
Inductance : 20mH -- 20H
Compact 1/16 DIN size fits into standard industry panel cutouts.
Microprocessor based for fast, reliable and accurate measurements.
Easy to calibrate by one keyboard. Degree ℃/℉ are switchable.
The large backlight LCD display pH or Conductivity and Temperature simultaneously.
DC current:200A/800A
AC current:200A/700A
AC voltage:600V
DC voltage:200V
Frequency Range from 9 kHz to 1.5 GHz
1.5 GHz Tracking Generator Kit
CO measurment from 0 to 500 ppm
Bandwidth : 20 MHz
Sample rate : 500MS/s
Max. Input voltage:400 V (peak)
Bandwidth : 20 MHz
Sample rate : 100MS/s
Max. Input voltage:400 V (peak)
Bandwidth : 20 MHz
Sample rate : 100MS/s
Max. Input voltage:400 V (peak)
Bandwidth : 60 MHz
Sample rate : 500MS/s
Max. Input voltage:400 V (peak)
Bandwidth : 60 MHz
Sample rate : 500MS/s
Max. Input voltage:400 V (peak)
Bandwidth : 100 MHz
Sample rate : 1GS/s
Max. Input voltage:400 V (peak)
Bandwidth : 100 MHz
Sample rate : 1GS/s
Max. Input voltage:400 V (peak)
Bandwidth : 60 MHz
Sample rate : 1GS/s
Max. Input voltage:400 V (peak)
Bandwidth : 100 MHz
Sample rate : 1GS/s
Max. Input voltage:400 V (peak)
Bandwidth : 100 MHz
Sample rate : 2GS/s
Max. Input voltage:400 V (peak)
Bandwidth : 200 MHz
Sample rate : 2GS/s
Max. Input voltage:400 V (peak)
Bandwidth: 20 MHz
Sample rate: 100MS/s
Input Impedance: 1MΩ ± 2%
Bandwidth 100MHz
Sample Rate 1GS/s
Max Input Voltage 400V (PK - PK)
Bandwidth : 30 MHz
Sample rate : 500MS/s
Max. Input voltage:400 V (peak)
Bandwidth : 50MHz
Sample rate : 500MS/s
10K record length
Bandwidth : 60 MHz
Sample rate : 500MS/s
Max. Input voltage:400 V (peak)
Bandwidth : 100 MHz
Sample rate : 1GS/s
Max. Input voltage:400 V (peak)
Max input voltage:400V
Bandwidth: 300 MHz
Sample rate: 2.5GS/s
Bandwidth : 300 MHz
Sample rate : 3.2GS/s
Max. Input voltage:400 V (peak)
Bandwidth :100MHZ
Sample rate : 1GS/s
Max. Input voltage:300 V (peak)
Bandwidth : 60 MHz
Sample rate :1GS/s
Max. Input voltage:200 V (peak)
Bandwidth : 60 MHz
Sample rate :1GS/s
Max. Input voltage:200 V (peak)
Bandwidth : 60 MHz
Sample rate : 1GS/s
Max. Input voltage:300 V (peak)
Bandwidth : 100 MHz
Sample rate :1GS/s
Max. Input voltage:300 V (peak)
Bandwidth : 100 MHz
Sample rate :1GS/s
Max. Input voltage:300 V (peak)
Bandwidth : 100 MHz
Sample rate : 1GS/s
Max. Input voltage:300 V (peak)
Bandwidth : 200 MHz
Sample rate :2GS/s
Max. Input voltage:300 V (peak)
Bandwidth: 100MHz
Sampling rate up to 1Gsa/s & 500Msa/s & 250Msa/s
bandwidth:25 MHz
sample rate:100MS/s
5K record length
bandwidth:25 MHz
sample rate:100MS/s
5K record length
Particle Counter
Item Number:
Maximum particle concentration:70,000 particles /L(coincidence loss max.5%)
Particle mass Counter
Item Number:
Particle mass Counter
Item Number:
Particle mass Counter
Item Number:
Rated Voltage AC 220V
Rated Power 2500W
Rated Current AC 10A
measuring range co2: from 0 to 5000 ppm
CO2 range: From 0 to 20000 ppm
Temperature range: 0 to +50°C
CO measurement range : 0 to 500ppm
CO measurement range : 0 to 500ppm