Sort by
Position
Name: A to Z
Name: Z to A
Price: Low to High
Price: High to Low
Created on
Display
36
48
72
per page
CO range:20PPM to 999PPM
alarm for more than 85db
*K type thermocouple
*Economical & accurate
*Single input model
*KJT 3-in-1 thermocouple meter
*Single input model
*RS232 interface
*Backlight display
IP54 protection
Max/ Min value indicator
Hold function
Optional thermocouple probe (K,J,T,S)
IP54 ABS housing
Temperature
Min.: -200 °C
Max.: 1760 °C
* PT 100 ohm + thermocouple type K,J,R,E,T.
* Max. measurement range 1370 oC ( type K ).
* 0.01o, 0.1o resolution, Memory ( Max., Min. ).
ranges:
- TN 100 - 1 chanel: from -40 to +120°C
- TN 101 - fixed probe: from -40 to +120°C
- TN 102 - 2 chanels: from -40 to +120°C
Temperature measurement(k) :℃-50~1300
Temperature measurement J:-50℃~1200
4times/s sampling rate
single-channel K/J thermometer
℃Temperature measurement K:-50℃~1300
℃Temperature measurement J:-50℃~1200
:Temperature:
Min.: -100 °C
Max.: 400 °C
-TR 50 : 1 channel
-TR 52 : 2 channels
* 1,000 oC no contact infrared Temp. measurement.
* 1400 oC type K thermometer.
* Dual laser for better targeting.
* Large LCD display with back light.
* 3 in 1, Infrared thermometer + Pt 100 ohm + Type K, J, R, E, T, intelligent.
* With laser target guide for IR measurement.
* IR range : -20 to 400 oC, Emissivity adjustment.
* -P circuit, LCD with display unit.
* Range : -200 to 1370 oC.
* Max., Min., Memory recall button.
* T1, T2, T1-T2, Type K/J.
* oC/oF, 0.1 degree/1 degree.
* Type K : -100 to 1300 oC.
*K type thermocouple
*Economical & accurate
*Dual input model
* Channels no. : 12 channels (CH1 to CH12) temerature measurement
* Sensor type : Type J/K/T/E/R/S thermocouple.
* Auto recorder or manual recorder.
Single or Dual Input: Dual T1-T2
Type K: -200°C ~1372°C
Body temperature range: 32 to 42.5 ° C
Range of surface temperature measurement: 0 to 60 ° C
Measuring distance: 5 to 15 cm
Non-Contact Infrared Body Forehead Thermometer 32°C ~ 42.5°C
Body Temp : 32~42.5deg
Surface Temp : 0~60deg
Room Temp : 10~40deg
Target Distance : 1~5cm
Temperature Range:-50°C~1050°C
accuracy:±1.8°C or ±1.8%
Distance to Spot Size:50:1
K type temperature probe
50:1 D:S ratio
99sets of data storage and USB data transmission
Temperature measurement range: -50~300C
Resolution: 0.1C
* Range : -30 oC to 305 oC .
* Mini pocket type.
* Laser target light.
* Emissivity adjustment, 0.20 to 1.00.
*Built-in laser pointer to improve aim
*Complies with FDA radiation performance standard 21 CFR Subchapter J
*Adjustable emissivity from 0.3 to 1.0
*Rubber-like hand grip designed
temperature range:-18 to +275 degrees C
8:1 distance-to-spot ratio
Visual image and infrared heat map blending
NEAR and FAR mode
Li-ion rechargeable battery
Optical : 30:1
Thermocouple K probe
measurment ranges
From -50 to +380°C
Optical : 12:1
Temperature range: -50 to 550oC
Accuracy: ±1.5% or ±1.5oC
Resolution: 0.1oC or 0.1F
Temperature range:-35 ~ 450°C
Display resolution:0.1°C
D:S (Distance to Spot Size) 10:10
Temperature range: -35 ~ 600°C
Display resolution:0.1°C
D:S (Distance and Spot Diameter Ratio):12:10
MAX / MIN / AVG / DIF display capability
Data storage capability
Laser marker
Backlight
The temperature range is from 200 to 2200 ° C
Temperature range -50ºC ~ 1250ºC
Data logging up to 100
T-C thermocouple measurement
USB data transfer
● Small size
● Proper design
● Backlit
● Laser marker
● Temperature range range from -32 to 280 ° C
● Voltage and constant current
● Temperature range range -50 to +1050 ° C
● Connect a computer
User selectable ℃ or ℉
Dual laser targeting
Automatic data hold
Auto power off
White backlit LCD display
Temperature range: -50 to 750oC
Accuracy: ±1.5% or ±1.5oC
Resolution: 0.1oC or 0.1F
Measurement Range (℃):-35℃~300
Optical resoluation: 6:1
Maximum/minimum measuring function
℃/℉ unit switch
LCD display
Automatic power off & battery indicator
Data hold
* Professional torque meter with separate probe.
* 15 Kg-cm torque sensor included.
* 3 units : 15 Kg-cm/13 LB-inch/147.1 N-cm.
Range:200Mohm /250V, 200Mohm /500V, 2000Mohm /1000V
AC voltage range:750V
Max open circuit voltage:3.3V
Resistance Range:200 ohm
Uses Radio Frequency to test effectiveness
of above ground insulators
AC voltage Range:600V
Input Impedance:4.5MΩ
Resistance Range:400Ω
Max open circuit voltage:12.8V
MEG OHMS Range:4000MΩ/250V,4000MΩ/500V,4000MΩ/1000V
To test for: RJ45/RJ11/BNC
To test for :short circuit,crossover, open circuit
Fast/slow checking modes conversion
Auto check of open/short/crossover circuit
To test for: HDMI/MINI-HDMI
Scan test mode
Full display test mode
To test for: RJ45/RJ11
To test for:short circuit, crossover, open circuit
Fast/slow checking modes conversion
Laser wavelength range 800nm~1700nm
Manual Range
Diode
Transistor
Continuity Buzzer
Voltage Sensitivity: 90 ~ 1000 VAC
Measuring range of resistance:10^3-10^12Ω
Measuring precision of resistance:±10%
measuring ranges:
- K: from -200 to +1300°C
- J: from -100 to +750°C
- T: from -200 to +400°C
- S: from 0 to 1760 °C
Termocouple:
-K: from -200 to 1300 °C
-J: from -100 to 750 °C
-T: from -200 to 400 °C
PT 100 probe: from -50 to 250 °C
Resolution: 0,1 (K, J, T) 0,01 Pt100
Large LCD with backlight displays PV and SV value.
Latching Hi/Low alarm 5A(250VAC) with manual reset.
Each channel has individual, independent and programmable alarm setpoint with alarm indicator.
Multi-mode for setting Channel number, ℃/℉, Auto/Manual, Scan rate, K/J/T/E type and Hi/Low
Suitable for K-, J-, T-, E-, R-, S- and N- type thermocouples.
Equipped with over limit alarm, over limit signal output and user self-debug features.
* Range : -40 to 1200 oC.
* Type K, dual channel, pocket size.
* Size : 131 x 70 x 25 mm.
Measuring range -50 to +150 °C
Accuracy ±0.2 °C (-20 to +80 °C)
±0.3 °C Remaining Range
Resolution 0.1 °C
این دماسنج جهت استفاده در حمام است و روی دوش نصب می شود
دمای بین 0 تا 100 درجه سانتیگراد را اندازه گیری میکند
Wide range: -50 to +300˚C (-58 to 572˚F)
MAX, MIN, HOLD modes
Automatic Power Off
Compact 5.9” size (15cm)
IP67 waterproof Protection
Measuring range -50 to +275 °C
(Accuracy±0.5°C(-20to+100°C±1°C(-50to+20.1°C±1%ofmv(+100
Resolution 0.1 °C
Measuring range -30 to +220 °C
(Accuracy ±0.5 °C (-30 to +99.9 °C) ±1.0 % of mv (+100 to +22°C
Resolution 0.1 °C
Measuring range -50 to +300 °C
Accuracy ±0.5 °C (-30 to +70 °C)
±0.5 °C ±0.5 % of mv (Remaining Range)
Resolution 0.1 °C