| LFO2-A4 Oxygen Sensor (O2 Sensor) PERFORMANCE |
| Output |
μA @ 20.9% O2 |
90 to 120 |
| Response time |
t90 (s) from 20.9% to 0 % O2 |
< 15 |
| Linearity |
% O2 deviation @ 10% O2 |
< 0.10 |
| |
|
|
| LFO2-A4 Oxygen Sensor (O2 Sensor) LIFETIME |
| Sensitivity @ -20℃ |
% (output @ -20℃/output @ 20℃) |
80 to 90 |
| Sensitivity @ 50℃ |
% (output @ 50℃/output @ 20℃) |
105 to 115 |
| Output drift |
% change in output @ 3 months |
< 1 |
| Operating life |
months until 85% original output of 20.9% O2 |
> 48 |
| |
|
|
| LFO2-A4 Oxygen Sensor (O2 Sensor) KEY SPECIFICATIONS |
| Temperature range |
℃ |
-30 to 50 |
| Pressure range |
kPa |
80 to 120 |
| Humidity range |
% rh continuous (0 to 99 %rh short term) |
5 to 95 |
| Storage period |
months @ 3 to 20℃ (store in sealed pot, open circuit) |
6 |
| Bias voltage |
mV |
-600 |
| Diameter |
mm (including label) |
20.0 |
| Height |
mm (including foam ring) |
17.4 |
| Weight |
g |
< 6 |