Sort by
Display
per page
Measuring range: 30~130 dBA
Accuracy: ±1.5 dB
10.0~99.99:RPM measurement
Up to 99999 display
10.0~9999.9:RPM measurement
Up to 99999 display
Dew point measurements
relative humidity &
ambient temperature measurements
HOLD function
temperature range:-20°C to 350°C
Spectral range:8–14 µm
temperature range:-20°C to 350°C
Spectral range:8–14 µm
temperature range:-20°C to 500°C
temperature range : -20°C to 300°C
Infrared Spectral Bandwidth: 8~14u
Accuracy:±2°C or ±2%
IP 65
registeration up to 100.000 points
four external entrances
ماکزیمم عمق تشخیص فلزات آهنی: 5 سانتی متر
ماکزیمم عمق تشخیص فلزات غیر آهنی: 8 سانتی متر
ماکزیمم عمق تشخیص سیم های مسی: 5 سانتی متر
ماکزیمم عمق تشخیص چوب: 2 سانتی متر
Measuring range: 30~130 dBA
Accuracy: ±1.5 dB
LEL : 0-100%, O2 : 0-30%
H2S : 0-100, CO : 0-1000
Spectral Band:3.4 - 5.1µm Standard
Thermal Imager:640 x 512, (15µm pitch) MWIR InSb
Detector Type:InSb
Pixel Pitch:10µm
Spectral Band:3.4µm – 5µm
Thermal sensitivity <50 mK
Spectral range:8–14 µm
(active pixels:80 (h) × 60(v
DC Voltage 200mV~600V
AC Voltage 200V~600V
DC Current 200μA~10A
Resistance 200Ω~2MΩ
*Multi Display conductivity with Temp. & real time stamped
*Auto or manual range measurement
*Collect data via RS232 by linking with PC
Frequency range:31.5HZ ~ 8KHZ
Dynamic range:50dB
Accuracy:±1.4dB
Frequency range:31.5HZ ~ 8KHZ
Dynamic range:50dB
Accuracy:±1.4dB
Sound Level range:35 ~ 130dB
accurancy:±3.0dB
Sound Level range:35 ~ 130dB
accurancy:±3.0dB
PM2.5 range:0-999.9ug/m3
Resolution:0.1ug/m3
Accuracy:15ug/m3
Ammonia range:O-10Oppm
Resolution:O.1ppm
Basic error:Less than +5% F.S
HCHO range:0-7.5 mg/m^3
resolution:0.01mg/m^3
Accuracy of HCHO <+-5FS
Multigas Detector for LEL, CO, H2S, and O2
Multigas Detector for LEL, CO, H2S, and O2
Measurement Principle:NH3 gas
range:0~100ppm
Number: 9389 9009
Measurement Principle:SO2 gas
range:0~20ppm
Number: 9389 9007
Measurement range: 0-100ppm
Resolution: 1ppm
maximum error: <50ppm: + 5ppm
maximum error: >50ppm: 10%
Measurement Principle:CO2 gas
range:0~5%vol
Number:9389 9005
Widest range detecting gases 0 to 5,000 ppm
Unrivalled sensitivity detects down to ppb levels
Measures 480 selectable compounds
Wide assortment of tubes to detect 300 gases and vapours
Gas tested: HCHO in the air
Measuring range: 0~3mg/m3
Resolution: 0.01mg/m3
Measurement Principle:CL2 gas
range:0~10ppm
Number: 9389 9008
H2S: 0 to 100 ppm
CO: 0 to 300 ppm
SO2: 0 to 50 ppm
O2: 0 to 25%
Measurement Principle:CO
range:0~ 1000ppm
Number: 9389 9004
Measurement Principle:H2S gas
H2S range:0-100ppm
Temperature H2S:-40 to +50°C
Measurement Principle:H2S gas
H2S range:0-100ppm
Temperature H2S:-40 to +50°C
H2S: 0 to 100 ppm
CO: 0 to 300 ppm
SO2: 0 to 50 ppm
O2: 0 to 25%
Oxygen range:0-25% by vol
Carbon Monoxide:0-500 PPM
Hydrogen Sulfide:0-100 PPM
Measurement Principle:H2S gas
range:0~ 100ppm
Number:9389 9006
H2S: 0 to 100 ppm
CO: 0 to 300 ppm
SO2: 0 to 50 ppm
O2: 0 to 25%
Mount sensor up to 100 ft. from transmitter
Mount sensor up to 100 ft. from transmitter
Choice of toxic, oxygen or flammable sensors
Detection Principle SF6: NIC
Range 0 – 2000 ppm SF6
Resolution 500 ppm SF6 / 10 ppm
Detection Principle SF6: NIC
Ultra high sensitivity with a 1 x 10-8 ml/sec
H2S: 0 to 100 ppm
CO: 0 to 300 ppm
SO2: 0 to 50 ppm
O2: 0 to 25%
Sensor:Photoionisation detector
Sensor:Photoionisation detector
Detects VOCs from 0 up to 20,000 ppm
Accuracy:± 5 % display reading ± 1 digit
Detects VOCs from 0 up to 5,000 ppm
Accuracy:± 5 % display reading ± 1 digit
Range 0 to 10 pp, 0 to 100, 0 to 1000 ppm
Measurement Principle:O2 gas
range:0~%30Vol
Number:9389 9003
Minimum Sensitivity PPM Model
Maximum Sensitivity PPB Model
detection of total aromatic compounds (TACs)
Unrivalled sensitivity detects down to ppb levels
Widest range detects gases 0 – 5,000 ppm
CO2, CH4: Infrared
O2, CO, H2S: Electrochemical
VOC: PID
Measurement Principle
Catalytic combustion:flammable gases
range:0~ 100LEL
Number: 9389 9001
Flammable, toxic and Oxygen versions available
Flammable 0-100% LEL
Oxygen 0-25% VOL
Measurement Principle
Electrochemical:oxygen and toxic gases
Catalytic combustion:flammable gases
Infrared:Carbon dioxide
Measurement Principle:H2 gas
range:0~1000ppm
Number: 9389 9002
Mount sensor up to 100 ft. from transmitter
Minimum Detection Limit:5 ppb
Range:0-100 ppm
Minimum Detection Limit:100 ppb
Range>100 ppm
Minimum Detection Limit:0.5 ppb
Range:0-3` ppm
Minimum Detection Limit:1 ppb
Range:0-40 ppm
Minimum Detection Limit:20 ppb
Range>200 ppm
Minimum Detection Limit:100 ppb
Range>4,000 ppm
Minimum Detection Limit:500 ppb
Range>10,000 ppm
Fits a broad variety of existing Honeywell products such as:
System 57, Touchpoint Pro, XNX / Modbus, Midas / Modbus, SPM Flex
Remote visibility on gas detection and worker location
Analysis method: Continuous scan FT-IR analyzer
Gas cell path: 5.0 m path length
Scanning rate: ≤ 15 sec per point