Sort by
Position
Name: A to Z
Name: Z to A
Price: Low to High
Price: High to Low
Created on
Display
36
48
72
per page
IP65 housing
with magnetic fixing
PT 100 range: -100 +400 °C
Measuring range
LV 111 : 0,8 to 25 m/s
Temperature : 0 to +50°C
Airflow : 0 to 99 999 m3/h
Temperature Infrared range-30 to +210 °C
Accuracy:±1.5 °C or ±1.5 % of mv
±2°C for Remaining Range
NTC temperature :-40 to +120 °C
internal sensor :
temperature : -20 to +70 °C
humidity: 5 to 95 %RH
Temperature Infrared range-50 to +300 °C
Accuracy:±1.5 °C for -20 to +100 °C
±2°C for Remaining Range
NTC probe: -40 to +120 °C
measuring ranges:
temperature:-20 to + 70 °C
humidity: 5 to 95 %RH
internal light: 0 to 10 000 lux
Voltage AC/DC:400.0 mV/1000 V
Current AC/DC:1.000 A (0.440 A continuous)
Resistance:400.0 oh,m, 4.000 k, 40.00 k, 400.0 k, 4.0 M, 40 M
Frequency:199.99 Hz, 1999.9 Hz, 19.999 kHz
print reports and display measurement data
Back-lighted graphic display with 3D effect
Keypad with 8 sensitive keys
USB transfer cable
Pressure range: from 0 to ±1000 mmH2O
differential pressure
IP54 ABS housing
Pressure range:
700 1100 mbar
humidity range:5 to 95 %RH
temperature range:-20 to +70°C
pressure range: +/-2500 Pa
Airflow range:from 0 - 99,999m3/h
Air velocity range:from 2 - 5 meters / sec
measure temperature from -40°C to 400°C
Air Velocity Range
0.15 to 3 meters per second
3.1 to 30 meters per second
Temperature Range: -20 to +80 degrees C
Air flow Range: 0 to 99999 cub. m/h
Measure up to 1000 V AC and DC
Measure current up to 10 A
Frequency to 200 kHz
Measurement ranges
Velocity : from 0,15 to 35 m/s
Airflow : from 0 to 99 999 m3/h
Measure up to 1000 VAC and DC
Measure current up to 20 A
9,999 µF capacitance range
Frequency up to 200 kHz
Resistance up to 50 MΩ
Measuring range
AIRFLOW:40 - 3500 m3/h
TEMPERATURE:From 0 - 50 deg. C
PRESSURE:From -2500 - +2500 Pa
AC Current: 0-2A/0-20A/0-200A/0-400A
AC/ DC voltage : 0-2V/0-20V/0-200V/0-600V
resistence:0~20MΩ
Display count: 2000
1000 V measurement range
10 Amps continuous
capacitance:1nF – 9,999 μF
Frequency:99.99Hz – 99.99kHz
Resistance:600.0 Ω – 50 MΩ
illuminance measurements: 0.1 to 150000 lux
with 0.1 lux accuracy for under 10 lux
with 1 percent accuracy for above 150,000 lux
Measures up to 1000 V ac and dc
measures up to 10 A
10,000 μF capacitance range
measuring range:0 to 200 000 lux
Illuminance range:0 to 10 000 lux
Temperature range -40ºC ~70ºC
℃Temp Accuracy:±0.5
Humidity range:0 to 100%RH
℃Temp. range:-40 to 70
℉Temp. accuracy:±1℃/1.8
Humidity range:0 to 100%RH
Humidity accuracy:±3.5%RH
External Sensor Range:-40°C to +99°C
Temp range:-25C-60C
Temp accuracy:±0.5C
℃Temp. range:-40 to 70
℃Temp. accuracy:±1
Temp range:-35C-70C
Temp accuracy:±0.5C
Frequency range 31.5HZ-8KHZ
Dynamic range 50 dB
Level ranges Auto: 30dB-130dB
Temp range:-30C-70C
Temp accuracy:±0.5C
Sensor Measurement Range:-25°C to +60°C
Temp range:-30 to 70°C
accuracy:±1.8°F,1°C
Max Resolution:0.1°
Temperature range -40ºC ~ 80ºC
Relative humidity range:0%RH~100%RH
Atmospheric pressure range:750hPa~1100hPa
℃Temp. range:-40 to 80
Temp. accuracy:± 0.5 °C - ± 2.0 °C
Humidity range:0 to 100%RH
Humidity accuracy:±3%RH-±5%RH
℃Temp. range:-40 to 80
Temp. accuracy:± 0.5°C - ±1.0°C,±2℃
DC and AC voltage (V):600V
DC and AC current (A):10A
Resistance (Ω):20MΩ
Selection of 11 types of thermocouple (K, J, E, T, R, S, N,…)
8 input temperature measurement
two pole AC voltage
continuity testers
Protected to IP64
Current range: 0.1A to 1000A AC
Frequency range: 10 Hz to 100 kHz
Auto calibration to assure the accuracy
Data store/ Data recall/ Data delete function
Sound velocity measurement
LCD backlight display
Metric/Imperial unit selection
Measures up to 1000V
and 10A AC/DC voltage and current
Temperature (℃):-40~1000
Frequency:400Hz~40MHz
Whole metal case, Shielding interference efficiently.
Zero calibration: auto returning to zero when you press the key after the probe is put on the specimen.
Battery information indicates the rest capacity of the battery,Auto sleep and auto power off function to conserve battery life.
Display: LCD with LED backlight .The brightness and the contrast of the LCD is adjustable.
DC and AC voltage (V):200.0mV~600V
DC and AC current (A):200.0μA~10.00A
Resistance :200.0Ω~20.00MΩ
Capacitance (F):2.000nF~2.000mF
DC and AC voltage (V):200.0mV~600V
DC and AC current:200.0μA~10.00A
Resistance :200.0Ω~200.0MΩ
Capacitance:2.000nF~2.000mF
DC and AC voltage (V):200.0mV~600V
DC and AC current:200.0μA~10.00A
Resistance:200.0Ω~200.0MΩ
Capacitance :2.000nF~2.000mF
DC and AC voltage:60mV/600V
AC and DC current :600μA/600mA/6A/10A
Capacitance :9.999nF/99.99mF
Spray and clean everywhere
- Detachable probe and screen
- Easy to operate
- Video output
- Durable body
AC/DC voltage6:600V
AC/DC current:20A
Resistance:60MΩ
Capacitance:60mF
Frequency:10Hz~1MHz
AC/DC voltage6:600V
AC/DC current:20A
Resistance:60MΩ
Capacitance:60mF
Frequency:10Hz~1MHz
Temperature (℃):-40℃~400
DC voltage: 600mV ~ 1000V
AC voltage: 600mV ~ 750V
AC and DC current (A): 600.0μA ~ 20A
Resistance (Ω): 600.0Ω ~ 60.00MΩ
DC voltage:600mV ~ 1000V
AC voltage:600mV ~ 750V
AC and DC current (A):600.0μA ~ 20A
DC and AC voltage:200mV/250V
AC and DC current:200μA/2A/10A
Resistance:200Ω/2MΩ/200MΩ
Capacitance:.2nF/2uF/20uF/200uF
DC and AC voltage:200mV/250V
DC current:200μA/200mA/10A
Resistance:200Ω/2kΩ/20MΩ
Easy to use with pock size and light weight
3 1/2 digital LCD display with LUX, fc, LOBAT, MAX, HOLD indication
Accurately display light level in terms of Foot Candles (Fc) or Lux Over wide range.
Measures from 0 to 50000 Lux/ Fc in four ranges with resolution 0.1Lux/Fc .
DC voltage: 200mV/2000mV/20V/200V/250V
AC voltage: 200V/250V
Resistance: 200Ω/2kΩ/20kΩ/200kΩ/20MΩ
- Extendable tube
- Detachable probe and screen
- Easy to operate
- Video output
- Durable body
Suitable for outlets or against wire insulation testing
Flashing red LED light indicator
Built-in bright flashlight with ON/OFF button
Illuminance Light Meter
Range: 0.1~50,000 Lux
* Large LCD display with bar graph display.
* 40.00/400.0/4,000/40,000/400,000 Lux.
* Lux, Foot-candle unit selection.
* Sensor meet C.I.E. spectrum, 2 filters.
DC voltage:200mV/2000mV/20V/200V/250V
AC voltage:200V/250V
DC and AC voltage (V):600V
DC and AC current (A):10A
Resistance (Ω):60MΩ
Capacitance (F):9.999mF
Frequency (Hz):60.00Hz~1.000MHz
Handheld Wind Speed Meter
Measuring Wind Speed
Measuring Temperature and Wind Chill
with Backlight and Max/Min
AC/DC Current:2000 A
AC/DC Voltage:1000V
Resistance: 40MΩ
Frequency:10MHz
Capacitance:40mF
DC voltage (V):600mV/6V/60V/600V
AC voltage (V):600V
DC current (A):10A
Resistance (Ω):600Ω/60MΩ
Capacitance (F) 9.999nF/ 9.999mF
* -P circuit, 2,000/20,000/50,000 Lux.
* Max., Min., Memory recall button.
* Lux, Ft-candle, % values, wide range.
* 4 light type select by push button.
AC Current:1000A
DC/AC Voltage:600V
Resistance:20MΩ
* Range : 0.5 to 35 m/s.
* Metal vane probe, heavy duty.
* m/s, ft/min, km/h, knots, mile/h, Temp..
* Temp. : -10 to 60 oC, oC/ oF.
* -P circuit, 2,000/20,000/50,000 Lux.
* Max., Min., Memory recall button.
* Lux, Ft-candle, % values, wide range.
* 4 light type select by push button.
DC and AC voltage :400mV/400V/1000V
DC and AC current:400uA/4A/10A
Resistance (Ω):400Ω/400kΩ/4MΩ/40MΩ
Capacitance (F):4nF/400μF/4mF/40mF