Sort by
Display
per page
Measuring range: 30~130 dBA
Accuracy: ±1.5 dB
*Remote vane with built-in sensor for measuring: Temp. / Dew Point / RH% / Wet Bulb / Air Velocity / Air volume
*Capacitance polymer sensor
*RS232 interface
fequency ranges:
9 ,30 Hz
temperature range:
-4 - 482°F
Thermal sensitivity ≤ 0.10°C
Noise (A Weighting):30~130dB
Resolution:0.1dB
Frequency response:31.5Hz~8kHz
Measuring range CO :0~500 ppm
CO measurement range : 0 to 500ppm
Measuring range CO :0~500 ppm
CO range : 0 to 1,000 ppm
Measuring range 0 to +1999 ppm
Measuring range CO :0~999 ppm
Measuring range CO2:0 to +10000 ppm
Light Measuring range:0 to 100000 Lux
temperature measuring range with different probes
detects smoke and smakeable firing
power supply:220v
with alarm
Measurement Range:0 to 1000PPM
Measurement Resolution:1PPM
Accuracy:±5% or ±10PPM
Detection of gas: air, carbon monoxide
Measuring range: 0 ~ 1000ppm
Resolution: 1ppm
Response time: 60 seconds
Sensor Type: Electrochemical CO sensor
Sensors protected with pump auto stop
Self test menu
Sensor O2 from 0 - 21 percent
sensor CO-H2 from 0 - 8000 parts per million
Step by step procedure
Sensor protection with pump stopping
Auto diagnostic menu
Measuring range 30 to 12500 rpm
Accuracy ±0.01 % of mv
Resolution 1 rpm
temperature measurement up to 1200 °C
Capture up to 5 additional measurements
Sound level Range:30 to 130dB
Frequency weighting: A/C
32000 Reading Internal Memory
flat surface probe
measuring range:-50-750°C
Measuring range CO2:0 to +10000 ppm
temperature measuring range with different probes
Sensitivity<50ppm(methane)
Range:0~10000ppm(methance)
Response Time<2 secs
* Air velocity : 0.4 to 30.0 m/s, ft/min., km/h, mile/h, knots.
* Barometer : 10 to 1100 hPa, mmHg, inHg.
* Humidity : 10% to 95% RH, Dew.
Measuring range 1 to 99999 rpm
Accuracy ±0.02 % of mv
Resolution 0.01 rpm (1 to 99.99 rpm)
0.1 rpm (100 to 999.9 rpm)
1 rpm (1000 to 99999 rpm)
measurement range:-50 to 200℃
tolerance:2.2℃
(Range:0~10000ppm(methane
Sensitivity:50ppm
Detection Gas: Fuel Gas
Sensitivity: 50ppm Methane
Alarm Mode: Sound and light alarm
Sensor Type: Low power semiconductor
Measuring range: 30~130 dBA
Accuracy: ±1.5 dB
Measuring range: 30~130 dBA
Accuracy: ±1.5 dB
Measuring range: 30~130 dBA
Accuracy: ±1.5 dB
Detection:Methane(LNG/CNG), Propane(LPG)
Range of detection:0 ~ 100%LEL
Detection:Methane(LNG/CNG), Propane(LPG)
sensitivity as low as 5ppm
Pump driven field adjustable range:10ppm
Sensor Type:Solid State
Pump driven field adjustable range:10ppm
Sensor Type:Solid State
16˝ inch Gooseneck detector
detect all halogen refrigerants
Adjustible sensitivity as low as 14 grams/year
Spectral Range: 7.5 µm – 13.5 µm
Sensor Technology:Uncooled VOx microbolometer
Spectral Range: 7.5 µm – 13.5 µm
Sensor Technology:Uncooled VOx microbolometer
Spectral Band:3.4 to ≥ 4.9µm Standard
Array format:640 x 512, 15µm pitch
Spectral Range:0.9 – 1.7 µm
Detector Type:Indium Gallium Arsenide
10.0~99.99:RPM measurement
Up to 99999 display
10.0~9999.9:RPM measurement
Up to 99999 display
Dew point measurements
relative humidity &
ambient temperature measurements
HOLD function
temperature range:-20°C to 350°C
Spectral range:8–14 µm
temperature range:-20°C to 350°C
Spectral range:8–14 µm
temperature range:-20°C to 500°C
temperature range : -20°C to 300°C
Infrared Spectral Bandwidth: 8~14u
Accuracy:±2°C or ±2%
ماکزیمم عمق تشخیص فلزات آهنی: 5 سانتی متر
ماکزیمم عمق تشخیص فلزات غیر آهنی: 8 سانتی متر
ماکزیمم عمق تشخیص سیم های مسی: 5 سانتی متر
ماکزیمم عمق تشخیص چوب: 2 سانتی متر
Measuring range: 30~130 dBA
Accuracy: ±1.5 dB
LEL : 0-100%, O2 : 0-30%
H2S : 0-100, CO : 0-1000
Spectral Band:3.4 - 5.1µm Standard
Thermal Imager:640 x 512, (15µm pitch) MWIR InSb
Detector Type:InSb
Pixel Pitch:10µm
Spectral Band:3.4µm – 5µm
Thermal sensitivity <50 mK
Spectral range:8–14 µm
(active pixels:80 (h) × 60(v
Frequency range:31.5HZ ~ 8KHZ
Dynamic range:50dB
Accuracy:±1.4dB
Frequency range:31.5HZ ~ 8KHZ
Dynamic range:50dB
Accuracy:±1.4dB
Sound Level range:35 ~ 130dB
accurancy:±3.0dB
Sound Level range:35 ~ 130dB
accurancy:±3.0dB
94dB and 114dB Sound Calibration at 1kHz
Output Frequency:1000Hz, ±4%
PM2.5 range:0-999.9ug/m3
Resolution:0.1ug/m3
Accuracy:15ug/m3
Ammonia range:O-10Oppm
Resolution:O.1ppm
Basic error:Less than +5% F.S
HCHO range:0-7.5 mg/m^3
resolution:0.01mg/m^3
Accuracy of HCHO <+-5FS
Multigas Detector for LEL, CO, H2S, and O2
Multigas Detector for LEL, CO, H2S, and O2
Measurement Principle:NH3 gas
range:0~100ppm
Number: 9389 9009
Measurement Principle:SO2 gas
range:0~20ppm
Number: 9389 9007
Measurement range: 0-100ppm
Resolution: 1ppm
maximum error: <50ppm: + 5ppm
maximum error: >50ppm: 10%
Measurement Principle:CO2 gas
range:0~5%vol
Number:9389 9005
Widest range detecting gases 0 to 5,000 ppm
Unrivalled sensitivity detects down to ppb levels
Measures 480 selectable compounds
Wide assortment of tubes to detect 300 gases and vapours
Gas tested: HCHO in the air
Measuring range: 0~3mg/m3
Resolution: 0.01mg/m3
Measurement Principle:CL2 gas
range:0~10ppm
Number: 9389 9008