Adjusting sound alarm rate
LED alarm
Automatically reset
- Japan made catalytic sensor provides excellent temperature independency to LNG/CNG
- Max value instantly displayed designed for patrol jobs
- %LEL and %V/V concentration unit optional
CO measurement range : 0 to 1000ppm
Range:0-100% Volume content
Test range:0-1000PPM
resolution:0.1PPM
Uncertainty<1.5%F.S
Test range:0-1000/3000 PPM
resolution:1 PPM
pricision:+ 5%FS
● Small volume, convenient to carry.
● Auto self-calibration when power on.
● Detection of two target gases at the same time.
ULTRASONIC TRANSMITTER/GENERATOR
Model: GS-400
* Ultrasonic transmitter for Gas Leakage Detector GS-5800
* Application : Air leaks around door & window gaskets & seals, Conduit & pipe identification, Windshield leaks...
* Bar LED to show the leakage level.
* Size : 255 x 70 x 28 mm.
Measuring range 1 to 999 ppm
0.1 to 4 Vol.%
Resolution 1 ppm / 0.1 Vol.%
Lower response threshold 10 ppm
Operating humidity 20 to 80 %RH
Operating temperature -18 to +50 °C
Detectable R22; R134a; R404A; R410A; R507; R438A; and all CFCs, HFCs, and HCFCs
Operating humidity 20 to 80 %RH
Reaction time < 1 s
Dimensions 190 x 57 x 42 mm
Operating temperature -20 to +50 °C
*Detect gas leakage of methane and propane
*Single color LED display 5 level leak
*Alarm and ready LED
Measuring range 0 to 20000 ppm
Lower response threshold 100 ppm
1st alarm limit 10000 ppm (20% LEL)
Measuring range:
0 to 10 000 ppm
0 to 1 %vol
0 to 20 %LEL
Measuring range:
0 to 10 000 ppm
0 to 1 %vol
0 to 20 %LEL
Detection of mixtures 5% hydrogen - 95% nitrogen
Detection of all the HCFC et HFC refrigerants
detects smoke and smakeable firing
power supply:220v
with alarm
Sensitivity<50ppm(methane)
Range:0~10000ppm(methance)
Response Time<2 secs
(Range:0~10000ppm(methane
Sensitivity:50ppm
Detection Gas: Fuel Gas
Sensitivity: 50ppm Methane
Alarm Mode: Sound and light alarm
Sensor Type: Low power semiconductor
Detection:Methane(LNG/CNG), Propane(LPG)
Range of detection:0 ~ 100%LEL
Detection:Methane(LNG/CNG), Propane(LPG)
sensitivity as low as 5ppm
Pump driven field adjustable range:10ppm
Sensor Type:Solid State
Pump driven field adjustable range:10ppm
Sensor Type:Solid State
16˝ inch Gooseneck detector
detect all halogen refrigerants
Adjustible sensitivity as low as 14 grams/year
LEL : 0-100%, O2 : 0-30%
H2S : 0-100, CO : 0-1000
PM2.5 range:0-999.9ug/m3
Resolution:0.1ug/m3
Accuracy:15ug/m3
Ammonia range:O-10Oppm
Resolution:O.1ppm
Basic error:Less than +5% F.S
HCHO range:0-7.5 mg/m^3
resolution:0.01mg/m^3
Accuracy of HCHO <+-5FS
Multigas Detector for LEL, CO, H2S, and O2
Multigas Detector for LEL, CO, H2S, and O2
Measurement Principle:NH3 gas
range:0~100ppm
Number: 9389 9009
Measurement Principle:SO2 gas
range:0~20ppm
Number: 9389 9007
Measurement range: 0-100ppm
Resolution: 1ppm
maximum error: <50ppm: + 5ppm
maximum error: >50ppm: 10%
Measurement Principle:CO2 gas
range:0~5%vol
Number:9389 9005
Widest range detecting gases 0 to 5,000 ppm
Unrivalled sensitivity detects down to ppb levels
Measures 480 selectable compounds
Wide assortment of tubes to detect 300 gases and vapours
Gas tested: HCHO in the air
Measuring range: 0~3mg/m3
Resolution: 0.01mg/m3
Measurement Principle:CL2 gas
range:0~10ppm
Number: 9389 9008
H2S: 0 to 100 ppm
CO: 0 to 300 ppm
SO2: 0 to 50 ppm
O2: 0 to 25%
Measurement Principle:CO
range:0~ 1000ppm
Number: 9389 9004
Measurement Principle:H2S gas
H2S range:0-100ppm
Temperature H2S:-40 to +50°C
Measurement Principle:H2S gas
H2S range:0-100ppm
Temperature H2S:-40 to +50°C
H2S: 0 to 100 ppm
CO: 0 to 300 ppm
SO2: 0 to 50 ppm
O2: 0 to 25%
Oxygen range:0-25% by vol
Carbon Monoxide:0-500 PPM
Hydrogen Sulfide:0-100 PPM
Measurement Principle:H2S gas
range:0~ 100ppm
Number:9389 9006
H2S: 0 to 100 ppm
CO: 0 to 300 ppm
SO2: 0 to 50 ppm
O2: 0 to 25%
Mount sensor up to 100 ft. from transmitter
Mount sensor up to 100 ft. from transmitter
Choice of toxic, oxygen or flammable sensors
Detection Principle SF6: NIC
Range 0 – 2000 ppm SF6
Resolution 500 ppm SF6 / 10 ppm
Detection Principle SF6: NIC
Ultra high sensitivity with a 1 x 10-8 ml/sec
H2S: 0 to 100 ppm
CO: 0 to 300 ppm
SO2: 0 to 50 ppm
O2: 0 to 25%
Sensor:Photoionisation detector
Sensor:Photoionisation detector
Detects VOCs from 0 up to 20,000 ppm
Accuracy:± 5 % display reading ± 1 digit
Detects VOCs from 0 up to 5,000 ppm
Accuracy:± 5 % display reading ± 1 digit
Range 0 to 10 pp, 0 to 100, 0 to 1000 ppm
Measurement Principle:O2 gas
range:0~%30Vol
Number:9389 9003
Minimum Sensitivity PPM Model
Maximum Sensitivity PPB Model
detection of total aromatic compounds (TACs)
Unrivalled sensitivity detects down to ppb levels
Widest range detects gases 0 – 5,000 ppm
CO2, CH4: Infrared
O2, CO, H2S: Electrochemical
VOC: PID
Measurement Principle
Catalytic combustion:flammable gases
range:0~ 100LEL
Number: 9389 9001
Flammable, toxic and Oxygen versions available
Flammable 0-100% LEL
Oxygen 0-25% VOL
Measurement Principle
Electrochemical:oxygen and toxic gases
Catalytic combustion:flammable gases
Infrared:Carbon dioxide
Measurement Principle:H2 gas
range:0~1000ppm
Number: 9389 9002
Mount sensor up to 100 ft. from transmitter
Minimum Detection Limit:5 ppb
Range:0-100 ppm
Minimum Detection Limit:100 ppb
Range>100 ppm
Minimum Detection Limit:0.5 ppb
Range:0-3` ppm
Minimum Detection Limit:1 ppb
Range:0-40 ppm